M66515FP
Absolute Maximum Ratings
(Unless otherwise noted, Ta = –20 to 70°C)
Symbol Parameter
Conditions
Value
Unit
VCC
Power supply voltage
−0.5 to +7.0
V
VI
Input voltage
CH, Vr
DATA, ENB, S/H
−0.3 to VCC
V
−0.3 to +7.0
V
VO
Output voltage
RO
−0.5 to +7.0
V
ISW
Switching current
150
mA
IB
Bias current
45
mA
Pd
Power dissipation
Mounted on board, with
1200
mW
Ta=25°C (see note)
Tstg
Storage temperature
−60 to +150
°C
Note: When Ta ≥ 25°C, derating at 9.6 mW/°C should be performed.
Recommended Operating Conditions
Symbol
VCC
ISW
IB
Topr
Parameter
Power supply voltage
Switching current
Bias current
Operating ambient temperature
Limits
Min
4.75
−20
(Unless otherwise noted, Ta = –20 to 70°C)
Unit
Typ
Max
5.0
5.25
V
120
mA
30
mA
70
°C
Rev.1.00, Sep.22.2003, page 6 of 11