Doc No.:
Issued Date: Jun. 04, 2008
Model No.: M185B1-L02
Tentative
Note (4) Definition of Luminance of White (LC):
Measure the luminance of gray level 255 at center point
LC = L (5)
L (x) is corresponding to the luminance of the point X at Figure in Note (6).
Note (5) Measurement Setup:
The LCD module should be stabilized at given temperature for 20 minutes to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 20 minutes in a windless room.
.tw LCD Module
LCD Panel
m USB2000
CS-1000T
.co Center of the Screen
500 mm
Light Shield Room
(Ambient Luminance < 2 lux)
lcd Note (6) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 9 points
s δW = Maximum [L (1), L (2) ……L (4), L (9)] / Minimum [L (1), L (2) …… L (4), L (9)]
.y Horizontal Line
D
D/10
D/2
9D/10
wW/10
1
2
3
wW W/2
4
5
6
X : Test Point
w X=1to9
9W/10
7
8
9
Active Area
19 / 25
Version 0.0