Error indication
After error correction, any code-word contain-
ing more than two bits random error or four bits
burst error (option) in address or message code-
word may be indicated from the error flag posi-
tion.
Data transfer
Data transfer is initiated once the code-word is
already received. When the HT9480 is ready to
transfer the received call data, an external in-
terrupt will be generated via output INT. Any
message data can be read by accessing the 1FH
address of the µC RAM map via the µC internal
bus.
The address word indicates call address, func-
tion bit setting, and decoder flags. The message
code-words are received and concatenated to a
valid call address word. The message words
derived from un-corrected message code-words.
Data transfer for a received call ends right after
the termination word is transferred.
Address word format
Bit Bit Bit Bit Bit Bit Bit Bit
7 654 3 2 1 0
Sync.
State
Call
address
Dup.
Call
0
Function
code
Bit 0: Bit 21 of the address code-word
Bit 1: Bit 20 of the address code-word
Bit 2=0 is to tell the difference between termi-
nation and address word format
Bit 3=1 if a duplicate code-word.
Bit 6
0
0
0
0
1
1
1
1
Bit 5
0
0
1
1
0
0
1
1
Bit 4
0
1
0
1
0
1
0
1
Call Address
RIC A
RIC B
RIC C
RIC D
RIC E
RIC F
Bit 7= 1 if an address code-word is received in
the data fail mode.
Interrupt indication
The HT9480 provides an internal data ready
interrupt and a battery fail interrupt. The in-
ternal data ready interrupt and battery fail
interrupt share the same pin connection.
Checking the battery fail interrupt bit (BF; bit
4 of 1EH) and the data ready interrupt bit (DR;
bit 7 of 1 EH) will tell which type of interrupt
has occurred. Both interrupt bits are active
low.
Out-of-range indication
The out-of-range condition occurs when the
time interval defined by SPF06, SPF07 does not
receive any preamble or sync code word. This
signal will be used as “loss of RF signal” indica-
tor.