PM4314 QDSX
DATA SHEET
PMC-950857
ISSUE 5
QUAD T1/E1 LINE INTERFACE DEVICE
• Squelches RZ signals with pulse amplitudes below 140mV and 105mV for
CEPT and T1, respectively.
• Typical minimum sensitivity of 50 mV at transformer primary with a 1:2 turns
ratio transformer allows for terminating or bridged performance monitoring
applications.
• Recovers a 1.544 MHz clock and DS-1 data or a 2.048 MHz clock and E1
data using a digital phase-locked loop to achieve high jitter accommodation.
• Accommodates up to 0.4 UI peak-to-peak, high frequency jitter to satisfy
AT&T TR 62411 and ITU-T G.823.
• Optionally outputs either dual rail recovered line pulses or a single rail DS-
1/E1 signal.
• Performs B8ZS or AMI decoding when processing a bipolar DS-1 signal and
HDB3 or AMI decoding when processing a bipolar E1 signal.
• Detects line code violations (LCVs), B8ZS/HDB3 line code signatures, and
16, 8, or 4 successive zeros.
• Accumulates up to 4095 line code violations (LCVs), for performance
monitoring purposes, over accumulation intervals defined by the period
between software write accesses to the LCV register.
• Detects loss of signal (LOS), which is defined as 10, 15, 31, 63, or 175
successive zeros.
• Detects both programmable inband loopback activate and deactivate code
sequences received in the DS-1 data stream when they are present for 5
seconds. Optionally, enters loopback mode automatically on detection of an
inband loopback code.
• Detects any pair of arbitrary inband codes from three to eight bits in length.
• The inband code detection algorithm operates in the presence of a 10-2 bit
error rate.
• Programmable to detect CSU (Channel Service Unit), network, and far-end
loopback codes.
• Optionally allows jitter attenuation of recovered clock and data, using a 2 X 48
bit FIFO.
• Optionally inserts unframed inband code sequences in place of recovered
data.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 2