LA4165M
Continued from preceding page.
• C10 : (10 µF)
Voice sensor transient suppression. This prevents the motor drive from being turned on by large transient
pulses.
• C11 : (47 µF)
Determines the time constant for motor drive hold after the voice sensor circuit turns off. The motor drive
remains on for approximately 4 to 5 seconds if the resistor in parallel with R5 is 300 k.
• C12 : (4.7 µF)
Together with series resistor R8, determines the preamp low-frequency cut-off. For C12 =4.7 µF and R8=100
, the cut-off is approximately 200 Hz. The cut-off can be set to approximately 100 or 300 Hz by giving C12
a value of 10 µF or 2.2 µF, respectively.
• C13 : (0.47 µF)
Preamp input coupling capacitor.
• C14 : (2200 µpF)
EMI suppression capacitor. Select this according to the characteristics of the record/play head.
• C15 : (3300 pF)
Microphone input high-frequency filter.
• C16 : (220 µF)
Reference voltage decoupling capacitor.
• C17 : (220 µF)
Head DC supply ripple filter.
• C18 : (220 µF)
Supply decoupling capacitor.
• C19 : (1 to 10 µF)
Reference resistor (R7) bypass capacitor. Setting should be performed according to motor characteristics.
• C20 : (1 µF)
Load (motor) bypass capacitor. Setting should be performed according to motor characteristics.
• R1 : (5 to 15 k)
Determines the flow of AC current through the head. Select this according to the head characteristics and ALC
level.
• R2 : (820 )
Determines the microphone input level at which the voice sensor starts operating when VR1 is at minimum.
Larger values for R2 give voice sensor operation at lower microphone input signal levels.
• R3 : (3 k)
Improves high-frequency response and reduces high-frequency distortion. Distortion above 5 kHz increases as
R3 decreases.
• R4 : (100 kto 3 M)
Determines ALC recovery time.
• R5 : (300 k)
Voice sensor circuit control current resistor. R5 and C11 form the motor drive hold-time constant.
• R6 : (20 to 70 k)
Determines motor speed. Select this according to the motor characteristics and the value of variable resistor
VR2.