Signal
BUF INH
IH ENA
IH DIR
RX DATA 0/1
RX DATA 0/1
TX INHIBIT 0/1
TX DATA
Pin Description (Cont.)
Hybrid
Sink or Source
Signal Description
SINK
SINK
SINK
SINK
SINK
SOURCE
SOURCE
Buffer Inhibit - A low on this line causes the Buffered Signals to assume a
high impedance state.
Internal Highway Enable - A low on this line enables the Internal Highway
transceiver to transmit or receive data which is controlled by the IH DIR Line.
Internal Highway Direction - Controls the direction of data through the
Internal Highway Transceiver.
High = To Subsystem
Low = From Subsystem
Positive Date In. This should be a TTL description of the positive, half of the
Manchester code data on the bus. It should be driven to a logic level “1” when
a predetermined positive threshold is exceeded on the bus.
Negative Data In. This should be a TTL description of the negative half of the
Manchester code data on the bus. It should be driven to a logic level “1” when
a predetermined negative threshold is exceeded on the bus.
Transmitter Enable. Goes low when the transmitter is transmitting. Should be
used to enable the bus drivers.
Positive Data Out - When this signal goes high the bus should be driven
positive.
Aeroflex Circuit Technology
10
SCDCT1999 REV B 8/14/01 Plainview NY (516) 694-6700