DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

BWR-5/165-D48 データシートの表示(PDF) - DATEL Data Acquisition products

部品番号
コンポーネント説明
メーカー
BWR-5/165-D48
Datel
DATEL Data Acquisition products  Datel
BWR-5/165-D48 Datasheet PDF : 5 Pages
1 2 3 4 5
MINIATURE, 5 WATT DC/DC CONVERTERS
BWR Models
1
+
CIN
2
+INPUT
–INPUT
3
+OUTPUT
4
COMMON
6
–OUTPUT
+
COUT
+
COUT
Figure 2. Using External Capacitors to Reduce
Input/Output Ripple/Noise
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. For DATEL BWR
5 Watt DC/DC Converters, you should use slow-blow type fuses with values
no greater than 0.5A.
CUSTOM CAPABILITIES
DATEL’s world-class design, development and manufacturing team stands
ready to work with you to deliver the exact power converter you need for
your demanding, large volume, OEM applications. And . . . we’ll do it on
time and within budget!
Our experienced applications and design staffs; quick-turn prototype capa-
bility; highly automated, SMT assembly facilities; and in-line SPC quality-
control techniques combine to give us the unique ability to design and
deliver any quantity of power converters to the highest standards of quality
and reliability.
We have compiled a large library of DC/DC designs that are currently used
in a variety of telecom, medical, computer, railway, aerospace and industrial
applications. We may already have the converter you need.
Contact us. Our goal is to provide you the highest-quality, most cost-effective
power converters available.
EMI RADIATED EMISSIONS
If you’re designing with EMC in mind, please note that all of DATEL’s BWR 5
Watt DC/DC Converters have been characterized for radiated and conducted
emissions in our new EMI/EMC laboratory. Testing is conducted in an
EMCO 5305 GTEM test cell utilizing EMCO automated EMC test software.
Radiated emissions are tested to the limits of FCC Part 15, Class B and
CISPR 22 (EN 55022) Class B. Correlation to other specifications can
be supplied upon request. Radiated emissions plots to FCC and CISPR 22
appear below. Its performance is typical of all models in the Family.
Published EMC test reports are available for each model number. Contact
DATEL’s Applications Engineering Department for details.
Radiated Emissions
FCC Part 15 Class B, 3 Meters
Converter Output = ±15Vdc @ ±132mA
80
70
60
FCC Class B Limit
50
40
30
20
10
0
Radiated Emissions
–10
–20
100
Frequency (MHz)
1000
Radiated Emissions
EN 55022 Class B, 10 Meters
Converter Output = ±15Vdc @ ±132mA
80
70
60
50
EN 55022 Class B Limit
40
30
20
10
0
Radiated Emissions
–10
–20
100
Frequency (MHz)
1000
®
®
INNOVATION and EXCELLENCE
ISO-9001 REGISTERED
DS0318
7/01
DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
Internet: www.datel.com Email: sales@datel.com
Data Sheet Fax Back: (508) 261-2857
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444
DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01
DATEL GmbH München, Germany Tel: 89-544334-0
DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do
not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark.
5

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]