1 2 3 4 5 6 7 8
12V SUPPLY
POR THRESHOLD
6V 9V
VREF TURN-ON
THRESHOLD
3.3V SUPPLY
TO EXTERNAL
MOSFET DRAIN
ADM1052
GATE DRIVE TO
EXTERNAL MOSFET
MOSFET GATE
THRESHOLD
CHANNEL 1
OR CHANNEL 2
OUTPUT VOLTAGE
CHANNEL 1
OR CHANNEL 2
OUTPUT CURRENT
NORMAL OUTPUT VOLTAGE
OUTPUT < 0.8 ؋ VREG
HICCUP MODE
HOLD-OFF TIME
DEVICE
ENTERS
HICCUP MODE
FAULT
CURRENT
2 AMPS
OFF
ON
1:40 DUTY CYCLE
Figure 2. Power-On Reset and Hiccup Mode
FAULT
REMOVED
APPLICATIONS INFORMATION
PCB LAYOUT
For optimum voltage regulation, the loads should be placed as
close as possible to the source of the output MOSFETs and
feedback to the sense inputs should be taken from a point as
close to the loads as possible. The PCB tracks from the loads
back to the sense inputs should be separate from the output
tracks and not carry any load current.
Similarly, the ground connection to the ADM1052 should be
made as close as possible to the ground of the loads, and the
ground track from the loads to the ADM1052 should not carry
load current. Correct and incorrect layout practice is illustrated
in Figure 3.
12V
VCC
FORCE 1
12V
VCC
FORCE 1
VIN
3.3V
SENSE 1
FORCE 2
SENSE 2
GND
I1
VOUT1
LOAD 1
VIN
3.3V
I2
VOUT2
LOAD 2
SENSE 1
FORCE 2
VOUT1
SENSE 2
GND
I1
LOAD 1
I1 + I2
VOUT2
I2
VOLTAGE DROP
BETWEEN OUTPUT
AND LOAD
LOAD 2
CORRECT
VOLTAGE DROP
IN GROUND LEAD
INCORRECT
Figure 3. Correct and Incorrect Layout Practice