DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

FS6385-XX データシートの表示(PDF) - AMI Semiconductor

部品番号
コンポーネント説明
メーカー
FS6385-XX
AMI
AMI Semiconductor AMI
FS6385-XX Datasheet PDF : 5 Pages
1 2 3 4 5
)6
7ULSOH 3// &ORFN *HQHUDWRU ,&
     X  T
)25 5(9,(:
March 2000
Table 2: Pin Descriptions
Key: AI = Analog Input; AO = Analog Output; DI = Digital Input; DIU = Input with Internal Pull-Up; DID = Input with Internal Pull-Down; DIO = Digital Input/Output; DI-3 = Three-Level Digital Input,
DO = Digital Output; P = Power/Ground; # = Active Low pin
PIN
TYPE
NAME
DESCRIPTION
1
DO
CLKA
Clock Output A
2
P
VSS
Ground
3
AI
XIN
Crystal Oscillator Feedback / External Clock Input
4
AO
XOUT
Crystal Oscillator Drive
5
DO
CLKB
Clock Output B
6
DO
CLKC
Clock Output C
7
P
VDD
Power (+3.3 volts)
8
DIU
SEL
Select Input (see Table 1)
3.0 Electrical Specifications
Table 3: Absolute Maximum Ratings
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. These conditions represent a stress rating only, and functional operation of the device at
these or any other conditions above the operational limits noted in this specification is not implied. Exposure to maximum rating conditions for extended conditions may affect device performance,
functionality, and reliability.
PARAMETER
SYMBOL
MIN.
MAX.
UNITS
Supply Voltage (VSS = ground)
Input Voltage, dc
Output Voltage, dc
Input Clamp Current, dc (VI < 0 or VI > VDD)
Output Clamp Current, dc (VI < 0 or VI > VDD)
Storage Temperature Range (non-condensing)
Ambient Temperature Range, Under Bias
Junction Temperature
Lead Temperature (soldering, 10s)
Input Static Discharge Voltage Protection (MIL-STD 883E, Method 3015.7)
VDD
VSS-0.5
7
V
VI
VSS-0.5
VDD+0.5
V
VO
VSS-0.5
VDD+0.5
V
IIK
-50
50
mA
IOK
-50
50
mA
TS
-65
150
°C
TA
-55
125
°C
TJ
125
°C
260
°C
2
kV
CAUTION: ELECTROSTATIC SENSITIVE DEVICE
Permanent damage resulting in a loss of functionality or performance may occur if this device is subjected to a high-energy elec-
trostatic discharge.
Table 4: Operating Conditions
PARAMETER
Supply Voltage
Ambient Operating Temperature Range
SYMBOL
VDD
TA
CONDITIONS/DESCRIPTION
3.3V ± 10%
2
,62
MIN.
3.0
0
TYP.
3.3
MAX.
3.6
70
UNITS
V
°C
3.24.00

Share Link: 