DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TP3201 データシートの表示(PDF) - Topro

部品番号
コンポーネント説明
メーカー
TP3201 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TP3201
1cell Li-ion battery
Protector IC
An output delay time for the over-discharge detection is fixed internally. Though the VDD voltage would be going down to a lower level than
VDET2 if it is within a time period of the output delay time, VD2 would not output a signal for turning “OFF” of discharge control
Nch-MOS-FET.
After detection of an over-discharge by VD2, supply current would be reduced to 0.3 µATYP. at VDD=2.0V and into standby, only the charger
detector is operating.
The output type of DOUT pin is CMOS having “H” level of VDD and “L” level of Vss.
VD3/Excess Current Detector, Short Circuit Protector
Both of the excess current detector and short circuit protector can work when both control Nch-MOS-FETs are in “ON” state.
When the V- pin voltage is going up to a value between the short protection voltage Vshort and excess current threshold VDET3, the excess
current detector operates and further soaring of V- pin voltage higher than Vshort makes the short circuit protector enabled. As a result the
external discharge control Nch-MOS-FET turns to “OFF” with the DOUT pin being at “L”.
An output delay time for the excess current detector is internally fixed, 8ms TYP. at Vote=3.0V. A quick recovery of V- pin level from a value
between Vshort and VDET3 within the delay time keeps the discharge control FET staying “ON” state.
When the short circuit protector is enabled, the DOUT would be "L" and its delay time would be 5µs TYP.
The V- pin has a built-in pull down resistor, TYP.100 k, connected to the Vss pin.
After an excess current or short circuit protection is detected, removing a cause of excess current or external short circuit makes an external
discharge control Nch-MOS-FET to an "ON" state automatically with the V- pin level being down to the Vss level through the built-in pull
down resistor.
When VDD voltage is higher than VDET2 at a time when the excess current is detected the TP3201 does not enter a standby mode, while VDD
voltage is lower than VDET2 the TP3201 enters a standby mode.
After detecting short circuit the TP3201 will not enter a standby mode.