DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACS760ELFTR-20B-T(2013) データシートの表示(PDF) - Allegro MicroSystems

部品番号
コンポーネント説明
メーカー
ACS760ELFTR-20B-T
(Rev.:2013)
Allegro
Allegro MicroSystems Allegro
ACS760ELFTR-20B-T Datasheet PDF : 15 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ACS760ELF-20B 12 V High-Side Hot-Swap Hall Effect Based Current Monitor IC
Pin-out Diagram
IP+ 1
IP+ 2
IP+ 3
IP+ 4
IP+ 5
IP+ 6
EN 7
VIOUT 8
ISET 9
CG 10
OCDLY 11
OPDLY 12
24 IP–
23 IP–
22 IP–
21 IP–
20 IP–
19 IP–
18 GATE
17 GND
16 FB–
15 FB+
14 S1SHORT
13 FAULT
Terminal List Table
Number
1-6
7
8
9
10
11
12
13
14
15
16
17
18
19-24
Name
IP+
EN
VIOUT
ISET
CG
OCDLY
OPDLY
¯F¯ ¯A ¯U ¯¯L¯ ¯T¯
S1SHORT
FB+
FB-
GND
GATE
IP–
Function
Primary sampled current conduction path input; power input pins: connected to VCC
Enable pin. Toggling this pin to the low state after a FAULT condition resets the ACS760.
Analog current level output. Output voltage on this pin is proportional to the current flowing from the IP+
pins to the IP– pins.
Terminal for RSET resistor. Sets Fault Current Threshold, IPF, via external resistor, RSET, connected between
this terminal and GND. Factory trimmed 100 μA current source flows out of this pin.
Terminal for CG capacitor. May be used to adjust the turn-on time and soft start control of an external
MOSFET, S1. Voltage on this pin limits inrush current through MOSFET S1. Set via external capacitance,
CG, connected between this pin and GND. This capacitor is charged by an internal 20 μA current source.
Terminal for external capacitor, COCD, Used to adjust delay for overcurrent shutdown, set via the external
capacitor, COCD, connected between this pin and GND.
Terminal for external capacitor, COPD, Used to adjust delay for overpower shutdown, set via the external
capacitor, COPD, connected between this pin and GND.
Active low; output signal for short circuit and 240 V*A overload faults; does not trip for S1 short circuit fault.
Connect a 1 kΩ pull-up resistor between this pin and the 3.3 V rail.
Active low; output signal for MOSFET S1 failure. Connect a 1 kΩ pull-up resistor between this pin and the
3.3 V rail.
Input of positive feedback on output voltage. Used to determine 240 V*A threshold by difference between
FB+ and FB– pins.
Input of negative feedback on output voltage. Used to determine 240 V*A threshold by difference between
FB+ and FB– pins. Pulling the FB– pin to 3.3 V, and the OPDLY pin to GND, disables the 240 V*A power
fault, which allows the ACS760 to operate purely in Current Mode.
Terminal for ground connection.
Terminal for external MOSFET, S1. Provides output voltage to drive S1. Current through S1 is controlled at
start-up by external capacitance connected between the CG pin and GND.
Primary sampled current conduction path output; power output pins.
Allegro MicroSystems, LLC
3
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]