DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ASCX データシートの表示(PDF) - Honeywell International

部品番号
コンポーネント説明
メーカー
ASCX
Honeywell
Honeywell International Honeywell
ASCX Datasheet PDF : 4 Pages
1 2 3 4
Microstructure Pressure Sensors
Signal Conditioned
0 psi to 1 psi up to 0 psi to 150 psi
ASCX Series
ASCX PERFORMANCE CHARACTERISTICS (4)
Characteristic
Offset (5)
Models ASCX15/30/100/150xN
Models ASCX01/05DN
Min. Typ. Max.
Unit
0.205 0.250 0.295 Volts
0.180 0.250 0.320 Volts
Output @ FS Pressure
4.750
Volts
Combined Pressure Linearity and Hysteresis (6)
±0.1 ±0.5 % FSO
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F] (7)
Models ASCX15/30/100/150xN
±0.2 ±1.0 % FSO
Models ASCX01/05DN
±0.2 ±1.5 % FSO
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F] (7)
Models ASCX15/30/100/150xN
±0.5 ±1.0 % FSO
Models ASCX01/05DN
±0.5 ±1.5 % FSO
Repeatability (8)
±0.2 ±0.5 % FSO
Response Time (9)
100
– Microsec.
SPECIFICATION NOTES
Note 1: Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
Note 2: Maximum pressure above which causes permanent sensor failure.
Note 3: Sensitivity is ratiometric to supply voltage.
Note 4: Performance specs are shown at reference conditions. Specifications apply for absolute pressure devices with pressure applied
to Port A. For gage devices, pressure is applied to Port B and Port A is left open for ambient. For differential pressures, Port B
is the high-pressure port. All differential devices feature dual pressure ports and can be used as gage or differential sensors.
For absolute devices, Port B is inactive.
Note 5: Offset calibration is at the lowest pressure for each given device.
Note 6: Linearity refers to the best straight line fit as measured for offset, full scale and ½ full-scale pressure.
Note 7: Temperature errors are the maximum shift over 0 °C to 70 °C [32 °F to 158 °F], relative to the 25 °C [77 °F] reading.
Note 8: Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 70 °C
[32 °F to 158 °F] after:
a) 100 temperature cycles, 0 °C to 70 °C [32 °F to 158 °F]
b) 1.0 million pressure cycles, 0 psi to Full-Scale Span.
Note 9: Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time.
ELECTRICAL CONNECTION
Pinout
ASCX Series
PIN 1) External Offset Adjustment
PIN 2) Vs
PIN 3) + Output
PIN 4) Ground
PIN 5) N/C
PIN 6) Do Not Use
Honeywell Sensing and Control 3

Share Link: 