M62420SP/ FP/ AFP
DATA and CLOCK
S D A (IN)
SCL
1
S D A (OUT)
S
start
2~7
8
9
ACK
acknowledge
P
stop
start
This term is defined by SDA(in) falling edge at SCL H .
stop
This term is defined by SDA(in) rising edge at SCL H .
CAUTION
The SDA(IN) level never change at SCK=H
except start and stop .
data transmisson
The SDA(IN) is enabled at SCL rising edge and H .
acknowledge
Transmitter must send H during ninth clock pulse of SCL .
The case of finished receiving , the receiver replies L synchronized to
falling edge of eighth pulse . And restart receiving the transmitted data
synchronized to falling edge of ninth pulse .
Rev.1.0, Sep.17.2003, page 10 of 16