DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX1874ETE(2003) データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX1874ETE Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Dual-Input, USB/AC Adapter, 1-Cell
Li+ Charger with OVP and Thermal Regulation
ELECTRICAL CHARACTERISTICS (continued)
(VUSB = VDC = VDCLV = VEN = VUSEL = 5V, VBATT = 4.2V, VTHRM = VREF / 2, Circuit of Figure 2, TA = -40°C to +85°C, unless otherwise
noted. Typical values are at TA = +25°C.) (Note 4)
PARAMETER
CONDITIONS
MIN TYP MAX UNITS
BATTERY VOLTAGE
BATT Regulation Voltage
BATT Prequal Voltage Threshold
BATT rising
4.1685
2.8
4.2315
V
3.2
V
REF Voltage (Buffered Output)
IREF = 0 to 500µA, 4V < VDC or VUSB < 6.5V;
2.94
does not affect BATT regulation accuracy
3.06
V
BATTERY CHARGING AND PRECHARGE CURRENT
DCI Voltage Range
DCI Voltage to BATT Current
VDCI = VREF
VDCI = VREF / 2
USB Charging Current
USEL = high
USEL = low
Prequal Charging Current
VBATT = 2.5V
BATT Input Current
BATT Shutdown Current
No DC or USB power, VBATT = 4.2V
EN = GND, USB and/or DC powered
0.1 x VREF
930
490
40
VREF
V
1070
mA
565
495
mA
95
70
mA
7.5
µA
2
µA
THERMISTOR MONITOR AND DIE-TEMPERATURE REGULATION
THRM COLD Trip Level
(Note 2)
THRM HOT Trip Level
(Note 2)
THRM Disable Threshold
0.72
0.28
50
0.76
0.30
150
VREF
VREF
mV
LOGIC INPUT/OUTPUTS AND GATE DRIVERS
DCOK Off-Leakage Current
UOK Off-Leakage Current
V DCOK = 12V, VDC = 0V
V UOK = 6.5V
DC input (% of charge current set at DCI)
8
CHG Threshold to Indicate Battery Full,
Battery Current Falling (Note 3)
USB input, USEL = 5V
20
(% of USB charging current)
CHG Logic-Low Output
Sinking 10mA sink
CHG Leakage Current
V CHG = 6.5V
EN, USEL Logic-Input High Level
1.6
1
µA
1
µA
20
%
30
0.4
V
1
µA
V
EN, USEL Logic-Input Low Level
EN, USEL Input Bias Current
0.4
V
1
µA
Note 1: BYP internally connects to the active power input (DCLV or USB). DCLV takes priority if both inputs are powered.
Note 2: These limits guarantee +5°C accuracy with 5% accuracy of thermistor beta (3450 nominal) with 2°C of hysteresis.
Note 3: The CHG output does not go high unless charge current is below the indicated threshold (as set by DCI) and the charger is in
voltage-mode operation. In 100mA USB mode, CHG goes high when the charger transitions from current to voltage mode.
Note 4: Specifications to -40°C are guaranteed by design, not production tested.
_______________________________________________________________________________________ 5

Share Link: 