Integrated Temperature
Controllers for Peltier Modules
Typical Operating Characteristics (continued)
(VDD = 5V, VCTLI = 1V, VFREQ = GND, RTEC = 1, circuit of Figure 1, TA = +25°C, unless otherwise noted.)
THERMAL STABILITY,
ROOM TEMPERATURE
THERMAL STABILITY,
HEATING MODE
TEMPERATURE ERROR
vs. AMBIENT TEMPERATURE
0.03
0.02
0.01
TEMPERATURE
TEMPERATURE
0.001°C/div
0.001°C/div
0
ITEC = +25°C
TA = +25°C
4s/div
TTEC = +25°C
TA = +5°C
4s/div
-0.01
-0.02
-0.03
-20 -10 0 10 20 30 40 50
AMBIENT TEMPERATURE (°C)
Pin Description
PIN
NAME
FUNCTION
1
OS2 Output Sense 2. OS2 senses one side of the differential TEC voltage. OS2 is a sense point, not a power
output.
2, 8, 29,
35
N.C. Not Internally Connected
3, 5
PGND2
Power Ground 2. Internal synchronous rectifier ground connections. Connect all PGND pins together at
power ground plane.
4, 6, 9
LX2 Inductor 2 Connection. Connect all LX2 pins together. Connect LX2 to LX1 when using the MAX1979.
7, 10
11
PVDD2
SHDN
Power 2 Inputs. Must be same voltage as VDD. Connect all PVDD2 inputs together at the VDD power plane.
Bypass to PGND2 with a 10µF ceramic capacitor.
Shutdown Control Input. Active-low shutdown control.
12
OT Under-Temperature Alarm. Open-drain output pulls low if temperature feedback falls 20mV
(typically +1.5°C) below the set-point voltage.
13
UT Under-Temperature Alarm. Open-drain output pulls low if temperature feedback falls 20mV
(typically +1.5°C) below the set-point voltage.
14
INTOUT Integrator Amp Output. Normally connected to CTLI.
15
INT- Integrator Amp Inverting Input. Normally connected to DIFOUT through thermal-compensation network.
16, 25,
GND Analog Ground. Connect all GND pins to analog ground plane.
26, 42, 43
17
DIFOUT Chopper-Stabilized Instrumentation Amp Output. Differential gain is 50 (FB+ - FB-).
18
FB- Chopper-Stabilized Instrumentation Amp Inverting Input. Connect to thermistor bridge.
19
FB+ Chopper-Stabilized Instrumentation Amp Noninverting Input. Connect to thermistor bridge.
20
BFB- Chopper-Stabilized Buffered FB- Output. Used to monitor thermistor bridge voltage.
21
BFB+ Chopper-Stabilized Buffered FB+ Output. Used to monitor thermistor bridge voltage.
22
AIN+ Undedicated Chopper-Stabilized Amplifier Noninverting Input
_______________________________________________________________________________________ 9