DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX5250(1996) データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX5250 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Low-Power, Quad, 10-Bit Voltage-Output DAC
with Serial Interface
Table 1. Serial-Interface Programming Commands
16-BIT SERIAL WORD
A1 A0
C1 C0
D9.................D0
MSB.............LSB
S1
S0
FUNCTION
0 0 0 1 10-bit DAC data 0 0 Load input register A; DAC registers unchanged.
0 1 0 1 10-bit DAC data 0 0 Load input register B; DAC registers unchanged.
1 0 0 1 10-bit DAC data 0 0 Load input register C; DAC registers unchanged.
1 1 0 1 10-bit DAC data 0 0 Load input register D; DAC registers unchanged.
0 0 1 1 10-bit DAC data 0 0 Load input register A; all DAC registers updated.
0 1 1 1 10-bit DAC data 0 0 Load input register B; all DAC registers updated.
1 0 1 1 10-bit DAC data 0 0 Load input register C; all DAC registers updated.
1 1 1 1 10-bit DAC data 0 0 Load input register D; all DAC registers updated.
0100
XXXXXXXXXX
X
X
Update all DAC registers from their respective input registers (also exit
shutdown mode).
1 0 0 0 10-bit DAC data 0 0 Load all DAC registers from shift register (also exit shutdown mode).
1100
XXXXXXXXXX X X Enter shutdown mode (provided PDL = 1).
0010
0110
XXXXXXXXXX
XXXXXXXXXX
X X UPO goes low (default).
X X UPO goes high.
0000
XXXXXXXXXX X X No operation (NOP) to DAC registers
1110
XXXXXXXXXX
X
X
Mode 1, DOUT clocked out on SCLK’s rising edge. All DAC registers
updated.
1010
XXXXXXXXXX
X
X
Mode 0, DOUT clocked out on SCLK’s falling edge. All DAC registers
updated (default).
“X” = Don’t care
Figure 5 shows the serial-interface timing requirements.
The chip-select pin (CS) must be low to enable the
DAC’s serial interface. When CS is high, the interface
control circuitry is disabled. CS must go low at least
tCSS before the rising serial clock (SCLK) edge to prop-
erly clock in the first bit. When CS is low, data is
clocked into the internal shift register via the serial-data
input pin (DIN) on SCLK’s rising edge. The maximum
guaranteed clock frequency is 10MHz. Data is latched
into the appropriate MAX5250 input/DAC registers on
CS’s rising edge.
The programming command Load-All-DACs-From-Shift-
Register allows all input and DAC registers to be simul-
taneously loaded with the same digital code from the
input shift register. The no operation (NOP) command
leaves the register contents unaffected and is useful
when the MAX5250 is configured in a daisy chain (see
the Daisy Chaining Devices section). The command to
change the clock edge on which serial data is shifted
out of DOUT also loads data from all input registers to
their respective DAC registers.
Serial-Data Output (DOUT)
The serial-data output, DOUT, is the internal shift regis-
ter’s output. The MAX5250 can be programmed so that
data is clocked out of DOUT on SCLK’s rising edge
(Mode 1) or falling edge (Mode 0). In Mode 0, output
data at DOUT lags input data at DIN by 16.5 clock
cycles, maintaining compatibility with Microwire,
SPI/QSPI, and other serial interfaces. In Mode 1, output
data lags input data by 16 clock cycles. On power-up,
DOUT defaults to Mode 0 timing.
User-Programmable Logic Output (UPO)
The user-programmable logic output, UPO, allows an
external device to be controlled via the MAX5250 serial
interface (Table 1).
10 ______________________________________________________________________________________