MAX6633/MAX6634/
MAX6635
12-Bit Plus Sign Temperature Sensors
with SMBus/I2C-Compatible Serial Interface
Write Byte Format
S
ADDRESS
WR
7 bits
Slave Address:
equivalent to chip-select
line of a 3-wire interface
ACK
COMMAND
8 bits
ACK
Command Byte: selects
register you are writing to
DATA
ACK
P
8 bits
Data Byte: data goes into the register set by
the command byte
Write Word Format
S
ADDRESS
WR
ACK COMMAND ACK DATA ACK DATA
ACK
P
7 bits
8 bits
8 bits
(MSB)
8 bits
(LSB)
Slave Address:
equivalent to chip-select
line of a 3-wire interface
Command Byte:
selects register you
are writing to
Data Bytes: data goes into the
register set by the command
byte
Read Byte Format
S ADDRESS WR ACK COMMAND ACK S ADDRESS RD
ACK
7 bits
8 bits
7 bits
Slave Address: equivalent
to chip-select line
Command Byte:
selects register you
are reading from
Slave Address: repeated due to
change in data-flow direction
DATA
///
P
8 bits
Data Byte: reads from the
register set by the command
byte
Read Word Format
S ADDRESS WR ACK COMMAND ACK S ADDRESS RD ACK DATA ACK DATA /// P
7 bits
8 bits
7 bits
8 bits
(MSB)
8 bits
(LSB)
Slave Address:
equivalent to chip-
select line
Command Byte:
selects register you
are reading from
Slave Address: repeated
due to change in data-flow
direction
Data Bytes: reads from the
register set by the command
byte
S = Start condition
P = Stop condition
Shaded = Slave transmission
/// = Not acknowledged
Figure 1. SMBus Protocols
A
B
C
D
EF
G
tLOW tHIGH
SMBCLK
SMBDATA
tSU:STA tHD:STA
tSU:DAT
tHD:DAT
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW
Figure 2. SMBus Write Timing Diagram
H
I JK
LM
tSU:STO tBUF
J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION
www.maximintegrated.com