DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX6645 データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX6645 Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Automatic PWM Fan-Speed Controllers with
Overtemperature Output
ABSOLUTE MAXIMUM RATINGS
VDD to GND ..............................................................-0.3V to +6V
PWM_OUT, OT, and FANFAIL to GND.....................-0.3V to +6V
FAN_IN1 and FAN_IN2 to GND...........................-0.3V to +13.2V
DXP_ to GND.........................................................-0.3V to +0.8V
FULLSPD, FULLSPD, TH_, TL_, TACHSET,
and OT_ to GND ..................................-0.3V to +(VDD + 0.3V)
FANFAIL, OT Current ..........................................-1mA to +50mA
Continuous Power Dissipation (TA = +70°C)
16-Pin QSOP (derate 8.3mW/°C above +70°C).......... 667mW
10-Pin µMAX (derate 5.6mW/°C above +70°C) ...........444mW
Operating Temperature Range .........................-40°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range ............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VDD = +3.0V to +5.5V, TA = -40°C to +125°C, unless otherwise noted. Typical values are at VDD = +3.3V, TA = +25°C.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
Operating Supply Voltage Range
VDD
+3.0
+5.5
V
Remote Temperature Error
VDD = +3.3V,
+20°C TRJ
+100°C
TA = +20°C to +60°C
TA = 0°C to +125°C
±2
°C
±3
Local Temperature Error
Temperature Error from Supply
Sensitivity
VCC = +3.3V
TA = +10°C to +70°C
TA = 0°C to +125°C
±0.2
±2.5
±3.5
°C
°C/V
Power-On-Reset (POR) Threshold
POR Threshold Hysteresis
Operating Current
Average Operating Current
Remote-Diode Sourcing Current
Conversion Time
Spin-Up Time
Startup Delay
VDD falling edge
IS
During a conversion
Duty cycle = 50%, no load
High level
MAX664_ _B_ _ _ _
MAX664_ _B_ _ _ _
1.5
2.0
2.5
V
90
mV
0.5
1
mA
0.5
mA
80
100
120
µA
125
ms
8
s
0.5
s
Minimum Fan-Fail Tachometer
Frequency
PWM_OUT Frequency
FPWM_OUT
DIGITAL OUTPUTS (OT, FANFAIL, PWM_OUT)
Output Low Voltage (OT)
VOL
ISINK = 1mA
Output Low Voltage
(FANFAIL, PWM_OUT)
VOL
ISINK = 6mA
ISINK = 1mA
Output-High Leakage Current
IOH
VOH = 3.3V
16
Hz
32
Hz
0.4
V
0.5
V
0.4
1
µA
2 _______________________________________________________________________________________