MC-4564EC726
DC Characteristics (Recommended Operating Conditions unless otherwise noted)
Parameter
Symbol
Test condition
Grade MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1
/CAS latency = 2 -A80
2,640 mA 1
tRC tRC (MIN.), IO = 0 mA
-A10
2,640
/CAS latency = 3 -A80
2,640
-A10
2,640
Precharge standby current in ICC2P CKE VIL (MAX.), tCK = 15 ns
5
power down mode
ICC2PS CKE VIL (MAX.), tCK =
286 mA
116
Precharge standby current in
non power down mode
ICC2N
CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
970 mA
ICC2NS CKE VIH (MIN.), tCK = ,
368
Input signals are stable.
Active standby current in
ICC3P CKE VIL (MAX.), tCK = 15 ns
430 mA
power down mode
ICC3PS CKE VIL (MAX.), tCK =
224
Active standby current in
non power down mode
ICC3N CKE VIH (MIN.), tCK = 15 ns, /CS VIH (MIN.),
Input signals are changed one time during 30 ns.
1,330 mA
ICC3NS CKE VIH (MIN.), tCK = ,
800
Input signals are stable.
Operating current
ICC4 tCK tCK (MIN.), IO = 0 mA
/CAS latency = 2 -A80
2,730 mA 2
(Burst mode)
-A10
2,370
/CAS latency = 3 -A80
3,180
5
CBR (Auto) Refresh current
ICC5
tRC tRC (MIN.)
5
5
5
-A10
/CAS latency = 2 -A80
-A10
/CAS latency = 3 -A80
-A10
2,820
4,980 mA 3
4,980
4,980
4,980
Self refresh current
Input leakage current
ICC6 CKE 0.2 V
II (L) VI = 0 to 3.6 V, All other pins not under test = 0 V
322 mA
–20 +20 µA
Input leakage current (CKE0)
Input leakage current
(/CS0-/CS3, DQMB0-DQMB7)
Output leakage current
IO (L) DOUT is disabled, VO = 0 to 3.6 V
–40 +40
–10 +10
–3 +3 µA
High level output voltage
VOH IO = –4.0 mA
2.4
V
Low level output voltage
VOL IO = +4.0 mA
0.4 V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open.
In addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open.
In addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).
Data Sheet M14460EJ2V0DS00
7

Share Link: 