Double-Balanced Mixer,
10 - 1500 MHz
MD-/MDS-149
V4
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Frequency Range
Conversion Loss
Isolation
DC Polarity
Test Conditions
RF, LO Ports
IF Port
LO to RF
LO to IF
RF to IF
Negative
Frequency
Units
Min
Typ
Max
10 - 1500
DC - 1500
MHz
—
—
—
MHz
10 - 1000 MHz
dB
—
—
7.5
1000 - 1500 MHz
dB
—
—
10
10 - 100 MHz
dB
35
—
—
100 - 1000 MHz
dB
30
—
—
1000 - 1500 MHz
dB
20
—
—
10 - 100 MHz
dB
35
—
—
100 - 1000 MHz
dB
20
—
—
1000 - 1500 MHz
dB
12
—
—
10 - 100 MHz
dB
30
—
—
100 - 1000 MHz
dB
18
—
—
1000 - 1500 MHz
dB
8
—
—
—
—
—
—
—
DC Offset
—
—
mV
—
<4
—
RF Input
1 dB Compression
1 dB Desensitization
—
dBm
—
0
—
—
dBm
—
-2.0
—
SSB Noise Figure
Within 1 dB of Conversion Loss
—
Max
—
—
—
—
Typical Two-Tone IM with a –10 dBm input, each input,
100-500 MHz
dB
—
48
—
Ratio
25 MHz and 35 MHz IF
500-1000 MHz
dB
—
43
—
1000-1500 MHz
dB
—
35
—
1. All specifications apply when operated at +7 dBm available LO power with 50 ohm source and load impedance.
Bottom View of SF-1
Typical Performance Curves
.385 Ref
4X .016 ± .002
.506
.220
.381
.165
.002
.000
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.