DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

PI74LPT244CSE データシートの表示(PDF) - Pericom Semiconductor

部品番号
コンポーネント説明
メーカー
PI74LPT244CSE
Pericom-Semiconductor
Pericom Semiconductor Pericom-Semiconductor
PI74LPT244CSE Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
PI74LPT244
3.3V 8-Bit Buffer /Line Driver
Capacitance (TA = 25°C, f = 1 MHz)
Parameters(1)
Description
Test Conditions
CIN
Input Capacitance
VIN = 0V
COUT
Output Capacitance
VOUT = 0V
Notes:
1. This parameter is determined by device characterization but is not production tested.
Typ
4.5
5.5
Max.
6
8
Units
pF
Power Supply Characteristics
Parameters Description
Test Conditions(1)
Min. Typ(2)
ICC
Quiescent Power Supply VCC = Max.
Current
VIN = GND
0.1
or VCC
ΔICC
Quiescent Power Supply VCC = Max.
Current
VIN = VCC
– 0.6V(3)
TTL Inputs HIGH
ICCD
Dynamic Power Supply(4) VCC = Max.,
VIN = VCC
50
Outputs Open OEX = GND
VIN = GND
One Bit Toggling
50% Duty Cycle
IC
Total Power Supply
VCC = Max., Outputs
VIN = VCC
0.6
Current(6)
Open fI = 10 MHZ
– 0.6V
50% Duty Cycle
VIN = GND
OEX = GND
One Bit Toggling
VCC = Max., Outputs
VIN = VCC
2.1
Open fI = 2.5 MHZ
– 0.6V
50% Duty Cycle
VIN = GND
OEX = GND
8 Bits Toggling
Notes:
1. For Max. or Min. conditions, use appropriate value specified under Electrical Characteristics for the applicable device.
2. Typical values are at Vcc = 3.3V, +25°C ambient.
3. Per TTL driven input; all other inputs at Vcc or GND.
4. This parameter is not directly testable, but is derived for use in Total Power Supply Calculations.
5. Values for these conditions are examples of the Icc formula. These limits are guaranteed but not tested.
6. IC =IQUIESCENT + IINPUTS + IDYNAMIC
IC = ICC + ΔICC DHNT + ICCD (fCP/2 + fINI)
ICC = Quiescent Current (ICCL, ICCH and ICCZ)
ΔICC = Power Supply Current for a TTL High Input
DH = Duty Cycle for TTL Inputs High
NT = Number of TTL Inputs at DH
ICCD = Dynamic Current Caused by an Input Transition Pair (HLH or LHL)
fCP = Clock Frequency for Register Devices (Zero for Non-Register Devices)
NCP = Number of Clock Inputs at fCP
fI = Input Frequency
NI = Number of Inputs at fI
All currents are in milliamps and all frequencies are in megahertz.
Max. Units
10 µA
500 µA
75 µA/
MHz
2.3 mA
4.7(5) mA
06-0181
4
PS2058F 06/05/06

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]