PM9607AP
CALIBRATION AND SETUP
Software is available to setup and calibrate the SA9607P
device. Download the SA9607P1.zip file from the SAMES web
site. From the following URL:
http://www.sames.co.za/emsoft/9607-1.zip
The latest version of the evaluation software and source code
is included in the zip file. The software was written with Borland
C++ Ver 3 and should run on any PC with DOS operating
system. The program was written as clear as possible so that it
can easily be modified for specific needs.
Start the program from the DOS prompt with:
c:\>sa9607p 1 1000
NAVIGATING
Use the cursor keys to move up and down between the
parameters listed under the “SA9607P Meter Parameters”
section. Press Enter on the parameter that needs to be
changed. The options available will be displayed. Type in the
correct option or value and press Enter again. The new setting
will be displayed.
A detailed description of the parameters listed on the screen
are described in the SA9607P datasheet. The following is a
description of the functionality of the SA9607P Meter
Parameters, displayed on the PC’s screen, figure 7.
sames
Vnom and Ima x
Vnom and Ima x make up the rated conditions of the module
(SA9607P’s Kr parameter). Vnom is the module’s rated voltage
and Ima xthe module’s rated current. The PM9607AP module is
designed for rated conditions of 230V/60A. The software
defaults to Vnom = 230V and Ima x= 60A.
LED Constant
LED Constant selects the module’s LED pulse rate (calibration
LED), which is the SA9607P’s CLED parameter. The options
available are 6400 p/kWh or 3200 p/kWh. Entering a ‘0’ will
enable the 1252 pulses/second (at rated conditions) mode for
fast calibration.
Counter Resol.
Counter resolution sets the modules counter resolution
(SA9607P’s CRES parameter). The options are 1,10 or
100p/kWh.
Counter PW
Counter PW set up the mechanical counter’s pulse width
(SA9607P’s CPW parameter). The available options are 71ms
and 142 ms. The PM9607AP module uses an impulse counter
with a pulse width of 71ms.
Channel1 Err / Channel2 Err
The module may be calibrated by entering the percentage
error in relation to a calibrated meter or Wh-Standard. The
percentage error is calculated as follows:
Error=(Energy from module – Real energy)/Real energy x 100
http://www.sames.co.za
Figure 7: Screen capture of the SA9607P setup program
7/16