AC Power: MP and P Series (cont.)
Surge Current Data
Time
Time*
2-Amp
4-Amp
(Seconds) (Cycles) Peak Amps Peak Amps
0.017
1
20
85
0.050
3
18
66
0.100
6
15
53
0.200
12
11
45
0.500
30
9
37
1
60
8.5
31
2
120
8
28
3
180
7.5
27
4
240
7
26
5
300
6.5
25
10
600
6
24
Note: *60 Hz
Thermal Ratings
Ambient temperature will affect the current rating.
DATA SHEET
Form 0859-180904
PAGE 10
Dimensional Drawings
NOTE: All dimensions are nominal.
OPTO 22 • 800-321-6786 • 1-951-695-3000 • www.opto22.com • sales@opto22.com