Technical Reference Notes
AIF12W300 DC-DC Series
Electrical Specifications (continued)
Shock test
The operating test condition is selected as typical of:
Acceleration
Pulse
Duration
Directions
ESD
Contact discharge
Air discharge
4g
Halfsine
22ms minimum
all 6 faces, 3 times in each positive
and negative directions
6KV
8KV
EMC (CONDUCTED)
FCC Class A and CISPR22 Class A – This is a system test and not a component level test. See Figure 4 for EMI Filter
Schematic.
MODEL: AIF12W300 SERIES
JUNE 2006