M61524FP
Recommended Operating Condition
Parameter
Supply voltage
Logic “H” level input voltage
Logic “L” level input voltage
Symbol
VCC
VIH
VIL
Conditions
VCC=9V GND reference
VCC=9V GND reference
Relationship between Data and Clock
(Ta=25°C, unless otherwise noted)
Limits
MIN
TYP
MAX
Units
8
9
10
V
2.2
—
5.5
V
0
—
0.6
V
When DATA is "H", latch signal is
created at the falling edge of CLOCK.
CLOCK
D0
D1
D2
D3
DATA
Data signal is read atthe rising edgeof CLOCK.
D13
D14
D15
Make "H" at the timing which
DATA of D0-D15 make latch.
Rev.1.0, Sep.19.2003, page 6 of 20