DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M69AR048B データシートの表示(PDF) - STMicroelectronics

部品番号
コンポーネント説明
メーカー
M69AR048B
ST-Microelectronics
STMicroelectronics ST-Microelectronics
M69AR048B Datasheet PDF : 29 Pages
First Prev 21 22 23 24 25 26 27 28 29
M69AR048B
Table 13. Standby Mode AC Characteristics
M69AR048B
Symbol
Alt.
Parameter
80, 85
Unit
Min
Max
tCLEX
tCSP
E2 Low Setup Time for Power-Down Entry
10
ns
tEXCH
tC2LP E2 Low Hold Time after Power-Down Entry
85
ns
tEHEV (1)
tCHH
E1 High Hold Time following E2 High after Power-Down Exit
(Deep Power-Down Mode only)
300
µs
tCHEL (2)
tCHHP
E1 High Hold Time following E2 High after Power-Down Exit
(not in Deep Power-Down Mode)
1
µs
tEHCH
tCHS
E1 High Setup Time following E2 High after Power-Down Exit
0
µs
tEHGL
tCHOX E1 High to G Invalid Time for Standby Entry
10
ns
tEHWL (3)
tCHWX E1 High to W Invalid Time for Standby Entry
10
ns
tτ (4)
tτ
Input Transition Time
1
25
ns
Note: 1. Applicable also to Power-up.
2. Applicable when 4M, 8M or 16M Partial Power-Down mode is programmed
3. Some data might be written into any address location if tEHWL (min) is not satisfied.
4. The Input Transition Time (tτ ) at AC testing is 5ns as shown below. If actual tτ is longer than 5ns, it may violate AC specification
of some timing parameters.
Figure 23. Power-Down Programming AC Waveforms
A0-A20
E1
MSB 2
tAVAX
MSB 2
tAXAV
MSB 2
MSB 2
MSB 2
PDCADD3
tAXAVL 4
G
W
LB, UB
DQ0-DQ15
RDa
Cycle 1
RDa
Cycle 2
RDa
Cycle 3
00
Cycle 4
PDCD4
RDb
Cycle 5
Cycle 6
AI07225c
Note: E2 = High.
1. All address inputs must be High from Cycle 1 to Cycle 5.
2. PDCADD stands for Power-Down Configuration Address. It must be compliant with the format specified in Table 6 otherwise the
data programmed during the Power-Down Program sequence may be incorrect.
3. PDCDAT stands for Power-Down Configuration Data. It must be compliant with the format specified in Table 5 otherwise the data
programmed during the Power-Down Program sequence may be incorrect.
4. tEHEL after the end of Cycle 6, the Power-Down Program is completed and the device returns to normal operation.
24/29

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]