+3.3V, 1Mbps, Low-Supply-Current
CAN Transceiver
Detailed Description
PIN
NAME
FUNCTION
1
TXD
Transmit Data Input. TXD is a CMOS/TTL-compatible input from a CAN controller. TXD has an
internal 75kΩ pullup resistor.
2
GND
Ground
3
VCC
Supply Voltage. Bypass VCC to GND with a 0.1µF capacitor.
4
RXD
Receive Data Output. RXD is a CMOS/TTL-compatible output.
5
SHDN
Shutdown Input, CMOS/TTL-Compatible. Drive SHDN high to put the MAX3051 in shutdown.
SHDN has an internal 75kΩ pulldown resistor to GND.
6
CANL
CAN Bus Line Low
7
CANH CAN Bus Line High
Mode-Select Input. Drive RS low or connect to GND for high-speed operation. Connect a resistor
8
RS
between RS and GND to control output slope. Drive RS high to put into standby mode (see the
Mode Selection section).
VCC
TXD
THERMAL
SHUTDOWN
TRANSMITTER
CONTROL
MAX3051
RS
MODE
SELECTION
RXD
RECEIVER
0.75V
VCC
CANH
CANL
SHUTDOWN
GND
SHDN
Figure 5. MAX3051 Functional Diagram
8 _______________________________________________________________________________________