A4988
DMOS Microstepping Driver with Translator
And Overcurrent Protection
VREG (VREG). This internally-generated voltage is used to
operate the sink-side FET outputs. The nominal output voltage
of the VREG terminal is 7 V. The VREG pin must be decoupled
with a 0.22 µF ceramic capacitor to ground. VREG is internally
monitored. In the case of a fault condition, the FET outputs of the
A4988 are disabled.
Capacitor values should be Class 2 dielectric ±15% maximum,
or tolerance R, according to EIA (Electronic Industries Alliance)
specifications.
Enable Input (¯E¯ ¯N¯ ¯A¯ ¯B¯ ¯L¯ ¯E¯). This input turns on or off all of the
FET outputs. When set to a logic high, the outputs are disabled.
When set to a logic low, the internal control enables the outputs
as required. The translator inputs STEP, DIR, and MSx, as well as
the internal sequencing logic, all remain active, independent of the
¯E¯ ¯N¯ ¯A ¯¯B¯ ¯L¯¯E¯ input state.
Shutdown. In the event of a fault, overtemperature (excess TJ)
or an undervoltage (on VCP), the FET outputs of the A4988 are
disabled until the fault condition is removed. At power-on, the
UVLO (undervoltage lockout) circuit disables the FET outputs
and resets the translator to the Home state.
Sleep Mode ( ¯S¯ ¯L¯ ¯E¯ ¯E¯ ¯P¯  ). To minimize power consumption
when the motor is not in use, this input disables much of the
internal circuitry including the output FETs, current regulator,
and charge pump. A logic low on the ¯L¯ ¯E¯ ¯E¯ ¯P pin puts the A4988
into Sleep mode. A logic high allows normal operation, as well as
start-up (at which time the A4988 drives the motor to the Home
microstep position). When emerging from Sleep mode, in order
to allow the charge pump to stabilize, provide a delay of 1 ms
before issuing a Step command.
5 A / div.
Fault
latched
t
Figure 4: Short-to-Ground Event
5 A / div.
Fixed off-time
t
Figure 5. Shorted Load (OUTxA → OUTxB) in Slow Decay Mode
Mixed Decay Operation. The bridge operates in Mixed
Decay mode, depending on the step sequence, as shown in Fig-
ures 9 through 13. As the trip point is reached, the A4988 initially
goes into a fast decay mode for 31.25% of the off-time, tOFF.
After that, it switches to Slow Decay mode for the remainder of
tOFF. A timing diagram for this feature appears in Figure 7.
Synchronous Rectification. When a PWM-off cycle is
triggered by an internal fixed-off time cycle, load current recircu-
lates according to the decay mode selected by the control logic.
This synchronous rectification feature turns on the appropriate
FETs during current decay, and effectively shorts out the body
diodes with the low FET RDS(ON). This reduces power dissipation
significantly, and can eliminate the need for external Schottky
diodes in many applications. Synchronous rectification turns off
when the load current approaches zero (0 A), preventing reversal
of the load current.
5 A / div.
Fixed off-time
Fast decay portion
(direction change)
t
Figure 6: Shorted Load (OUTxA → OUTxB) in Mixed Decay Mode
Allegro MicroSystems, LLC
10
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com