36 3625 01
2 of 4
Environmental conditions
Temperature range
-40 °C/+125 °C – 3625 01
-40 °C/+130 °C – 3625 01 M08
-40 °C/+130 °C – 3625 01 M20
-25 °C/+150 °C – auf Anfrage 1
1 upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body
PA, V-2 according to UL94 – 3625
01
PA, V-2 according to UL94 – 3625
01 M08
PA, V-0 according to UL94 – 3625
01 M20 1
Contact spring
CuSn, silver-plated
1 M08: component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment
acc. to IEC 60335-1 (flame < 2 s)<br>M20: material halogen-free, GWFI 960 °C (0.75 mm), GWIT 775 °
C (0.75 mm)
Mechanical data
Insertion force
≤ 50 N 1
Withdrawal force
≥ 15 N 1
Keying proposals
at www.lumberg.com �
1 measured with a polished flat steel pin, nominal thickness 0.8 mm
Connectable conductors for IDT area
Construction
Section min.
Section max.
Insulation diameter
Approved cables
discrete conductor, notched flat
cable 5.0 mm
0,75 mm²
1,5 mm²
≤ 3,0 mm
at www.lumberg.com �
Electrical data (at Tamb 20 °C)
Contact resistance
Rated current
Rated voltage
Material group
Insulation resistance
≤ 5 mΩ
16 A (1,5 mm², TU 70 °C)
12 A (1,0 mm², TU 70 °C)
250 V AC
I (IEC)/0 (UL) (CTI ≥ 600) – 3625 01
IIIa (IEC)/2 (UL) (CTI ≥ 250) – 3625
01 M08
I (IEC)/2 (UL) (CTI ≥ 600) – 3625 01
M20
> 10 GΩ
01/2018