DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

24IMS6-12-9 データシートの表示(PDF) - Power-One Inc.

部品番号
コンポーネント説明
メーカー
24IMS6-12-9 Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Industrial Environment
DC/DC Converters < 40W
IMS6 Series
Immunity to Environmental Conditions
Table 8: Mechanical stress
Test Method
Ca Damp heat
steady state
Ea Shock
(half-sinusoidal)
Eb Bump
(half-sinusoidal)
Fc Vibration
(sinusoidal)
Fda Random vibration
wide band
reproducibility
high
Kb Salt mist, cyclic
(sodium chloride
NaCl solution)
Standard
IEC/DIN IEC 60068-2-3
MIL-STD-810D section 507.2
IEC/EN/DIN EN 60068-2-27
MIL-STD-810D section 516.3
IEC/EN/DIN EN 60068-2-29
MIL-STD-810D section 516.3
IEC/EN/DIN EN 60068-2-6
MIL-STD-810D section 514.3
IEC 60068-2-35
IEC/EN/DIN IEC 60068-2-52
Test Conditions
Temperature:
Relative humidity:
Duration:
40 2 C
93 +2/-3 %
56 days
Acceleration amplitude:
Bump duration:
Number of bumps:
100 gn = 981 m/s2
6 ms
18 (3 each direction)
Acceleration amplitude:
Bump duration:
Number of bumps:
40 gn = 392 m/s2
6 ms
6000 (1000 each direction)
Acceleration amplitude:
Frequency (1 Oct/min):
Test duration:
0.35 mm (10...60 Hz)
5 gn = 49 m/s2 (60...2000 Hz)
10...2000 Hz
7.5 h (2.5 h each axis)
Acceleration spectral density: 0.05 gn2/Hz
Frequency band:
10...500 Hz
Acceleration magnitude:
Test duration:
4.9 gn rms
3 h (1 h each axis)
Concentration:
Duration:
Storage:
Storage duration:
Number of cycles:
5% (30 C)
2 h per cycle
40 C, 93% rel. humidity
22 h per cycle
3
Status
Unit not
operating
Unit
operating
Unit
operating
Unit
operating
Unit
operating
Unit not
operating
Table 9: Temperature specifications, valid for air pressure of 800...1200 hPa (800...1200 mbar)
Temperature
Characteristics
Conditions
TA Ambient temperature 1
TC Case temperature
TS Storage temperature 1
Operational 2
Non operational
1 MIL-STD-810D section 501.2 and 502.2
2 See Thermal Considerations
Standard -9
min
max
–40
71
–40
100
–40
100
Table 10: MTBF and device hours
MTBF
Ground Benign
Ground Fixed
Ground Mobile
MTBF acc. to MIL-HDBK-217F
TC = 40 C
TC = 40 C
TC = 70 C
TC = 50 C
48IMS6-05-9
2'651'000 h
349'000 h
124'000 h
119'000 h
1 Statistical values, based on an average of 4300 working hours per year and in general field use
Unit
C
Device Hours 1
Edition 1 06.00

Share Link: 