A1244
Chopper-Stabilized, Two Wire
Hall-Effect Latch
ELECTRICAL CHARACTERISTICS Valid at TA = –40°C to 150°C, TJ < TJ(max), CBYP = 0.01 μF, through operating supply voltage
range; unless otherwise noted
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Unit
Supply Voltage1,2
Supply Current
Supply Zener Clamp Voltage
Supply Zener Clamp Current
VCC
ICC(L)
ICC(H)
VZ(sup)
IZ(sup)
Operating, TJ 165 °C
-I1 B < BRP
-I2 B < BRP
B > BOP
ICC(L)(max) + 3 mA, TA = 25°C
VZ(sup) = 28 V
3.0
24
V
5
6.9
mA
2
5
mA
12
17
mA
28
V
ICC(L)(max)
+ 3 mA
mA
Reverse Supply Current
IRCC
VRCC = –18 V
–1.6
mA
Output Slew Rate3
di/dt
No bypass capacitor, capacitance of probe
CS = 20 pF
90
mA/ μs
Chopping Frequency
fc
700
kHz
Power-Up Time2,4,5
ton
25
μs
Power-Up State4,6,7
POS ton < ton(max) , VCC slew rate > 25 mV / μs
ICC(H)
1VCC represents the generated voltage between the VCC pin and the GND pin.
2The VCC slew rate must exceed 600 mV/ms from 0 to 3 V. A slower slew rate through this range can affect device performance.
3Measured without bypass capacitor between VCC and GND. Use of a bypass capacitor results in slower current change.
4Power-Up Time is measured without and with bypass capacitor of 0.01 μF, B < BRP – 10 G. Adding a larger bypass capacitor would cause longer
Power-Up Time.
5Guaranteed by characterization and design.
6Power-Up State as defined is true only with a VCC slew rate of 25 mV / μs or greater.
7For t > ton and BRP < B < BOP , Power-Up State is not defined.
MAGNETIC CHARACTERISTICS1 Valid at TA = –40°C to 150°C, TJ < TJ (max); unless otherwise noted
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Unit2
Magnetic Operating Point
BOP
5
80
G
Magnetic Release Point
BRP
–80
–5
G
Hysteresis
BHYS
BOP – BRP
40
110
G
1Relative values of B use the algebraic convention, where positive values indicate south magnetic polarity, and negative values indicate north
magnetic polarity; therefore greater B values indicate a stronger south polarity field (or a weaker north polarity field, if present).
2 1 G (gauss) = 0.1 mT (millitesla).
Allegro MicroSystems, LLC
3
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com

Share Link: 