DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

A29040BV データシートの表示(PDF) - AMIC Technology

部品番号
コンポーネント説明
メーカー
A29040BV Datasheet PDF : 29 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
A29040B Series
Table 4. A29040B Command Definitions
Command
Sequence
(Note 1)
Bus Cycles (Notes 2 - 4)
First
Second
Third
Fourth
Fifth
Sixth
Addr Data Addr Data Addr Data Addr Data Addr Data Addr Data
Read (Note 5)
1 RA RD
Reset (Note 6)
1 XXX F0
Autoselect Manufacturer ID
(Note 7) Device ID
4 555 AA
4 555 AA
2AA 55
2AA 55
555 90 X00 37
555 90 X01 86
Continuation ID
4 555 AA 2AA 55 555 90 X03 7F
Sector Protect Verify 4 555 AA 2AA 55
(Note 8)
555 90 SA 00
X02 01
Program
4 555 AA 2AA 55 555 A0 PA PD
Chip Erase
6 555 AA 2AA 55 555 80 555 AA 2AA 55 555 10
Sector Erase
6 555 AA 2AA 55 555 80 555 AA 2AA 55 SA 30
Erase Suspend (Note 9)
1 XXX B0
Erase Resume (Note 10)
1 XXX 30
Legend:
X = Don't care
RA = Address of the memory location to be read.
RD = Data read from location RA during read operation.
PA = Address of the memory location to be programmed. Addresses latch on the falling edge of the WE or CE pulse,
whichever happens later.
PD = Data to be programmed at location PA. Data latches on the rising edge of WE or CE pulse, whichever happens first.
SA = Address of the sector to be verified (in autoselect mode) or erased. Address bits A18 - A16 select a unique sector.
Note:
1. See Table 1 for description of bus operations.
2. All values are in hexadecimal.
3. Except when reading array or autoselect data, all bus cycles are write operation.
4. Address bits A18 - A11 are don't cares for unlock and command cycles, unless SA or PA required.
5. No unlock or command cycles required when reading array data.
6. The Reset command is required to return to reading array data when device is in the autoselect mode, or if I/O5 goes high
(while the device is providing status data).
7. The fourth cycle of the autoselect command sequence is a read cycle.
8. The data is 00h for an unprotected sector and 01h for a protected sector. See "Autoselect Command Sequence" for more
information.
9. The system may read and program in non-erasing sectors, or enter the autoselect mode, when in the Erase Suspend mode.
10. The Erase Resume command is valid only during the Erase Suspend mode.
PRELIMINARY (December, 2004, Version 0.2)
10
AMIC Technology, Corp.

Share Link: 