HV510
Electrical Characteristics (for VDD = 5V, VPP = 240V, TA = 250C)
DC Characteristics
Symbol
Parameter
Min Typ Max Units
IDD
VDD supply current
4 mA
IDDQ
Quiescent VDD supply current
IPP
High voltage supply current
200
µA
0.25
mA
0.25
mA
IIH
High-level logic input current
IIL
Low-level logic input current
VOH
High-level output
220
HVOUT
175
10
µA
-10
µA
V
V
VOL
Low-level output
Data out
HVOUT
Data out
VDD -1V
V
25
V
1.0
V
VOC
HVOUT clamp voltage
VPP +1.5 V
-1.5
V
IOH
Output Source Current
1.0
mA
0.8
mA
Conditions
fCLK = 8MHz, fDATA = 4MHz
LE = LOW
All VIN = 0V or VDD
VPP = 240V All outputs high
VPP = 240V All outputs low
VIH = VDD
VIL = 0V
VPP = 240V, IHVOUT = -0.5mA
VPP = 200V, lHVOUT = -0.5mA
IDOUT = -100µA
VDD = 5V, IHVOUT = 1mA
IDOUT = 100µA
IOL = 1mA
IOL = -1mA
VPP = 240V
VPP = 200V
AC
Characteristics1
(For
V
DD
=
5V,
V
PP
=
200V,
T
A
=
25°C)
Symbol
Parameter
Min Typ
fCLK
Clock frequency
tW
Clock width high and low
62
tSU
Data setup time before clock rises
35
tH
Data hold time after clock rises
30
tWLE
Width of latch enable pulse
80
tDLE
LE delay time after rising edge of clock
35
tSLE
LE setup time before rising edge of clock
40
tON, tOFF
Time from latch enable to HVOUT
tDHL
Delay time clock to data out high to low
tDLH
Delay time clock to data out low to high
tr, tf
All logic inputs
Note:
1. Shift register speed can be as low as DC as long as Data Set-up and Hold Time meet the spec.
Max Units
8 MHz
ns
ns
ns
ns
ns
ns
6.0
µs
125 ns
125 ns
5
ns
Conditions
CL = 20pF
CL = 20pF
CL = 20pF
Recommended Operating Conditions
Symbol
Parameter
Min
Typ
Max
VDD
Logic supply voltage
VPP
High voltage supply
VIH
High-level input voltage
VIL
Low-level input voltage
TA
Operating free-air temperature
Notes:
Power-up sequence should be the following:
1. Connect ground.
2. Apply VDD.
3. Set all inputs (Data, CLK, Enable, etc.) to a known state.
4.5
5.0
5.5
60
240
VDD -0.9
VDD
0
0.9
-40
+85
4. Apply VPP.
5. The VPP should not drop below VDD or float during operation.
Power-down sequence should be the reverse of the above.
Units
V
V
V
V
°C
2

Share Link: 