ADM1033
Functional Description
The ADM1033 is a localand remotetemperature
monitor and fan controller for use in a variety of
applications, including microprocessorbased systems. The
device accurately monitors remote and ambient temperature
and uses that information to quietly control the speed of a
cooling fan. Whenever a fan stalls, the device asserts a
FAN_FAULT output.
The ADM1033 features a THERM I/O. As an input, this
measures assertions on the THERM pin. As an output, it
asserts a low signal to indicate when the measured
temperature exceeds the programmed THERM temperature.
The ADM1033 communicates over an SMBus 2.0 interface.
Its LOCATION input determines which version of SMBus to
use, as well as the SMBus address (in fixed and discoverable
mode) and the LOCATION bits in the UDID (in
ARPcapable mode).
Internal Registers
Table 1 gives a brief description of the ADM1033’s
principal internal registers. For more detailed information
on the function of each register, refer to Table 31.
Serial Bus Interface
The ADM1033 communicates with the master via the
2wire SMBus 2.0 interface. It supports two versions of
SMBus 2.0, determined by the value of the LOCATION
input’s resistors.
The first version is fully ARPcapable. This means that it
supports address resolution protocol (ARP), allowing the
master to dynamically address the device on powerup. It
responds to ARP commands such as “Prepare to ARP.”
The second SMBus version, fixed and discoverable, is
backwards compatible with SMBus 1.0 and 1.1. In this mode,
the ADM1033 powers up with a fixed address, which is
determined by the state of the LOCATION pin on powerup.
NOTE: When using the ADM1033, Addresses 0xC2 and
0xCA should not be used by any other device on the bus.
Location Input
The LOCATION input is a resistor divider input. It has
multiple functions and can specify the SMBus version (in
fixed and discoverable or ARPcapable modes); the SMBus
address (in fixed and discoverable mode); and the LLL bits
(in UDID in ARPcapable mode).
The voltage of this 8level input is set by a potential
divider. The voltage on LOCATION is sampled on powerup
and digitized by the onchip ADC to determine the
LOCATION input value. Because the LOCATION input is
sampled only at powerup, changes made while power is
applied have no effect.
VCC
R1
PIN 13
ADM1033
LOCATION
R2
GND
Figure 15. Bootstrapping the LOCATION Input
SMBus 2.0 ARPCapable Mode
In ARPcapable mode, the ADM1033 supports features
such as address resolution protocol (ARP) and unique device
identifier (UDID). The UDID is a 128bit message that
describes the ADM1033’s capabilities to the master. The
UDID also includes a vendor specific ID for functionally
equivalent devices.
VCC
ARP
LOCATION = 111 1.5kΩ
ARP
LOCATION = 110 1kΩ
ARP
LOCATION = 101 1kΩ
ARP
LOCATION = 100 1kΩ
FD
ADDRESS = 53h 1kΩ
FD
ADDRESS = 52h 1kΩ
FD
ADDRESS = 51h 1.5kΩ
FD
ADDRESS = 50h
GND
ADM1033 1
ADM1033 2
ADM1033 3
ADM1033 4
ADM1033 5
ADM1033 6
ADM1033 7
ADM1033 8
Figure 16. Setting Up Multiple ADM1033 Addresses
in SMBus 2.0 ARPCapable Mode
In SMBus 2.0 mode, this vendor specific ID is generated
by an onchip random number generator. This should enable
two adjacent ADM1033s in the same system to powerup
with a different vendor specific ID, allowing the master to
identify the two separate ADM1033’s and assign a different
address to each.
The state of the LOCATION input on powerup is also
reflected in the UDID. This is useful when there is more than
one ADM1033 in the system, so the master knows which one
it is communicating with. The complete UDID is listed in
Table 3.
The SMBus 2.0 master issues both general and directed
ARP commands. A general command is directed at all ARP
devices. A directed command is targeted at a single device
once an address has been established. The PEC byte must be
used for ARP commands. (Refer to the Packet Error
Checking (PEC) section.)
The ADM1033 responds to the following commands:
Prepare to ARP (general)
Reset device (general and directed)
Get UDID (general and directed)
Assign address (general)
http://onsemi.com
8