ADuM1200/ADuM1201
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-Output)1
Capacitance (Input-Output)1
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Symbol Min Typ
RI-O
1012
CI-O
1.0
CI
4.0
θJCI
46
θJCO
41
Max Unit Test Conditions
pF
f = 1 MHz
pF
°C/W Thermocouple located at center of
package underside
°C/W
1 The device is considered a 2-terminal device; Pins 1, 2, 3, and 4 are shorted together, and Pins 5, 6, 7, and 8 are shorted together.
REGULATORY INFORMATION
The ADuM1200/ADuM1201 have been approved by the following organizations:
Table 5.
UL
Recognized under 1577 Component
Recognition Program1
2500 V rms isolation voltage
CSA
Approved under CSA Component
Acceptance Notice #5A
VDE
Certified according to
DIN EN 60747-5-2 (VDE 0884 Part 2): 2003-012
Basic insulation, 560 V peak
Complies with DIN EN 60747-5-2 (VDE 0884
Part 2): 2003-01, DIN EN 60950 (VDE 0805): 2001-12;
EN 60950: 2000, Reinforced insulation, 560 V peak
File E214100
File 205078
File 2471900-4880-0001
1 In accordance with UL1577, each ADuM120x is proof-tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 µA).
2 In accordance with DIN EN 60747-5-2, each ADuM120x is proof-tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection
limit = 5 pC).
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal
Clearance)
Tracking Resistance (Comparative
Tracking Index)
Isolation Group
Symbol
L(I01)
Value
2500
4.90 min
L(I02) 4.01 min
0.017 min
CTI
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1 minute duration
Measured from input terminals to output terminals, shortest
distance through air
Measured from input terminals to output terminals, shortest
distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. B | Page 10 of 20