ADuM1410/ADuM1411/ADuM1412
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance2
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Symbol
RI-O
CI-O
CI
θJCI
θJCO
Min Typ
1012
2.2
4.0
33
28
Max Unit Test Conditions
Ω
pF
f = 1 MHz
pF
°C/W
°C/W
Thermocouple located at
center of package underside
1 The ADuM141x device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM141x have been approved by the organizations listed in Table 5.
Table 5.
UL 1
Recognized under 1577
component recognition
program1
CSA
Approved under CSA Component
Acceptance Notice #5A
VDE2 (ADuM1411 and ADuM1412 pending)
Certified according to DIN EN 60747-5-2
(VDE 0884 Part 2): 2003-012
1 In accordance with UL1577, each ADuM141x is proof tested by applying an insulation test voltage ≥3000 V rms for 1 second (current leakage detection limit = 5 μA).
2 In accordance with DIN EN 60747-5-2, each ADuM141x is proof tested by applying an insulation test voltage ≥1050 V peak for 1 second (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN EN 60747-5-2 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
CTI
Value
2500
7.7 min
8.1 min
0.017 min
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1 minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. E | Page 10 of 20