ADuM1440/ADuM1441/ADuM1442/ADuM1445/ADuM1446/ADuM1447
Data Sheet
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation within the safety limit data only. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marked on packages denotes DIN V VDE V 0884-10 approval.
Table 14.
Description
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method b1
Input-to-Output Test Voltage, Method a
After Environmental Tests Subgroup 1
After Input and/or Safety Test Subgroup 2
and Subgroup 3
Highest Allowable Overvoltage
Surge Isolation Voltage
Safety Limiting Values
Case Temperature
Total Power Dissipation at 25°C
Insulation Resistance at TS
Test Conditions/Comments
VIORM × 1.875 = Vpd(m), 100% production test,
tini = tm = 1 sec, partial discharge < 5 pC
VIORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec,
partial discharge < 5 pC
VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec,
partial discharge < 5 pC
VPEAK = 10 kV, 1.2 µs rise time, 50 µs, 50% fall time
Maximum value allowed in the event of a failure
(see Figure 3)
VIO = 500 V
Symbol Characteristic Unit
VIORM
Vpd(m)
I to IV
I to III
I to II
40/105/21
2
560
1050
VPEAK
VPEAK
Vpd(m)
Vpd(m)
VIOTM
VIOSM
840
672
3500
4000
VPEAK
VPEAK
VPEAK
VPEAK
TS
150
°C
IS1
1.64
W
RS
>109
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0
50
100
150
200
AMBIENT TEMPERATURE (°C)
Figure 3. Thermal Derating Curve, Dependence of Safety-Limiting Values
with Case Temperature per DIN V VDE V 0884-10
RECOMMENDED OPERATING CONDITIONS
Table 15.
Parameter
Operating Temperature
Supply Voltages1
Input Signal Rise and Fall Times
Symbol
TA
VDD1, VDD2
Value
−40°C to +125°C
2.25 V to 3.6 V
1.0 ms
1 All voltages are relative to their respective grounds. See the DC Correctness
section for information on immunity to external magnetic fields.