ADuM2210/ADuM2211
Data Sheet
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance2
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Symbol
RI-O
CI-O
CI
θJCI
θJCO
Min Typ Max Unit Test Conditions
1012
Ω
2.2
pF
f = 1 MHz
4.0
pF
33
°C/W Thermocouple located at
28
°C/W center of package underside
1 Device considered a 2-terminal device: Pin 1 through Pin 8 are shorted together and Pin 9 through Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM221x are approved by the organizations listed in Table 5. Refer to Table 10 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL
Recognized under 1577 Component
Recognition Program1
Single Protection
5000 V rms Isolation Voltage
File E214100
CSA
Approved under CSA Component
Acceptance Notice #5A
Basic insulation per CSA 60950-1-07 and IEC
60950-1, 600 V rms (848 V peak) maximum
working voltage
RW-16 package:
Reinforced insulation per CSA 60950-1-07
and IEC 60950-1, 380 V rms (537 V peak)
maximum working voltage; reinforced
insulation per IEC 60601-1 125 V rms
(176 V peak) maximum working voltage
RI-16 package:
Reinforced insulation per CSA 60950-1-07
and IEC 60950-1, 400 V rms (565 V peak)
maximum working voltage; reinforced
insulation per IEC 60601-1 250 V rms
(353 V peak) maximum working voltage
File 205078
VDE
Certified according to DIN V VDE V 0884-10 (VDE V
0884-10): 2006-122
Reinforced insulation, 846 V peak
File 2471900-4880-0001
1 In accordance with UL1577, each ADuM221x is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 μA).
2 In accordance with DIN V VDE V 0884-10, each ADuM221x is proof tested by applying an insulation test voltage ≥1590 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap
Symbol
L(I01)
Minimum External Tracking (Creepage) RW-16 Package L(I02)
Minimum External Tracking (Creepage) RI-16 Package L(I02)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Isolation Group
Value
5000
8.0 min
Unit
V rms
mm
7.7 min mm
8.3 min mm
0.017 min mm
>175
V
IIIa
Conditions
1-minute duration
Distance measured from input terminals to output
terminals, shortest distance through air along the PCB
mounting plane, as an aid to PC board layout
Measured from input terminals to output terminals,
shortest distance path along body
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. A | Page 10 of 2

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]