60
50
40
30
20
10
0
35 40 45 50 55 60 65 70 75
SELF-TEST (mV)
Figure 16. X-Axis Self-Test Response at 25°C
40
35
30
25
20
15
10
5
0
420 430 440 450 460 470 480 490 500 510 520 530
CURRENT (μA)
Figure 17. Supply Current at 25°C
ADXL320
60
50
40
30
20
10
0
35 40 45 50 55 60 65 70 75
SELF-TEST (mV)
Figure 18. Y-Axis Self-Test Response at 25°C
Figure 19. Turn-On Time—CX, CY = 0.1 μF, Time Scale = 2 ms/DIV
Rev. 0 | Page 9 of 16