ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
MIN MAX UNIT
Device Voltage
0
+8
VDC
RF Input Power
-
+15 dBm
Storage Temperature
-40 +150
°C
Channel Temperature
-
+150
°C
Stresses in excess of the absolute ratings may cause permanent
damage. Functional operation is not implied under these conditions.
Exposure to absolute ratings for extended periods of time may
adversely affect reliability.
AGB3300
Table 3: Operating Ranges
PARAMETER
MIN TYP MAX UNIT
Operating Frequency: f
250
-
3000 MHz
Device Voltage: VDD
-
+5
+6
VDC
Case Temperature: Tc
-40
-
+85
oC
The device may be operated safely over these conditions; however,
parametric performance is guaranteed only over the conditions defined
in the electrical specifications.
Data Sheet - Rev 2.1
3
06/2003