AH1801
MICROPOWER, ULTRA-SENSITIVE HALL EFFECT
SWITCH
Absolute Maximum Ratings (at TA = 25°C)
Symbol
Vdd
B
Ts
Characteristics
Supply voltage
Magnetic flux density
Storage Temperature Range
PD
Package Power Dissipation
TJ Maximum Junction Temp
SC59
DFN2020-3
DFN2020-6
Recommended Operating Conditions (TA = 25°C)
Values
Unit
7
V
Unlimited
-65 to +150
°C
230
mW
150
°C
Symbol
Vdd
TA
Parameter
Supply Voltage
Operating Temperature Range
Conditions
Operating
Operating
Rating
Unit
2.5~5.5
V
-40 to +85
°C
AH1801 Rev. 7
4 of 10
www.diodes.com
FEBRUARY 2009
© Diodes Incorporated