AH1809
Absolute Maximum Ratings (Note 6) (@TA = +25°C, unless otherwise specified.)
Symbol
VDD
VOUT
VDD REV
VOUT_REV
IOUTPUT
B
PD
Ts
TJ
ESD HBM
Supply Voltage (Note 7)
Output Pin Voltage (Note 7)
Reverse Supply Voltage
Reverse Output Pin Voltage
Output current (source and sink)
Magnetic Flux Density
Parameter
Package Power Dissipation
Storage Temperature Range
Maximum Junction Temperature
Human Body Model ESD capability
SC59 and SOT553
SIP-3L
Rating
Unit
7
V
7
V
-0.3
V
-0.3
V
2.5
mA
Unlimited
230
mW
230
-65 to +150
°C
+150
°C
6
kV
Notes:
6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
7. The absolute maximum VDD of 7V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to
operate the device at the absolute maximum rated conditions for any period of time.
Recommended Operating Conditions (@TA = +25°C, unless otherwise specified.)
Symbol
VDD
VOUT_MAX
TA
Parameter
Supply Voltage
Maximum output pin voltage
Operating Temperature Range
Operating
Operating
Operating
Conditions
Rating
Unit
2.5 to 5.5
V
5.5
V
-40 to +125
°C
Electrical Characteristics (@TA = +25°C, VDD = 3V, unless otherwise specified.)
Symbol
VOUT_ON
Ioff
Parameter
Output On Voltage (VOL)
Output Leakage Current
IDD(awake)
IDD(sleep)
Supply Current
IDD(sleep)
IDD(avg)
Tawake
Tperiod
D.C.
Average Supply Current
Awake Time
Period
Duty Cycle
Conditions
Min
Typ
Max
Unit
IOUT = 1mA
0.1
0.3
V
VOUT = 5.5V, Output off
< 0.1
1
µA
During ‘awake’ period,
TA = +25°C, VDD = 3V
During ‘awake’ period,
TA = -40 to +125°C, VDD = 2.5V to 5.5V
3
6
mA
12
mA
During ‘sleep’ period,
TA = +25°C, VDD = 3V
5
10
µA
During ‘sleep’ period,
TA = -40 to +125°C, VDD = 2.5V to 5.5V
28
µA
TA = +25°C, VDD = 3V
8
16
µA
TA = -40 to +125°C, VDD = 2.5V to 5.5V
40
µA
(Note 8)
(Note 8)
-
75
125
µs
75
125
ms
0.1
%
Note:
8. When power is initially turned on, the operating VDD must be within its correct operating range (2.5V to 5.5V) to guaranteed the output sampling.
The output state is valid after the second operating cycle (typical 150ms).