APPLICATION NOTE • APN1005
Table 3 shows the bill of materials used.
Designators
C1
C2
C3
C4
C5
C6
C6
D1
D2
L1
L2
R1
R10
R11
R2
R3
R4
R5
R6
R7
R8
R9
V1
V2
Comment
0603AU100JAT9 (AVX)
0603AU100JAT9 (AVX)
0603AU101JAT9 (AVX)
0603AU101JAT9 (AVX)
0603AU101JAT9 (AVX)
0603AU102JAT9 (AVX)
0603AU102JAT9 (AVX)
SMV1265-011 (Skyworks)
SMV1265-011 (Skyworks)
LL1608-F33NJ (TOKO)
LL1608-F33NJ (TOKO)
CR10-330J-T (AVX)
CR10-242J-T (AVX)
CR10-102J-T (AVX)
CR10-330J-T (AVX)
CR10-121J-T (AVX)
CR10-121J-T (AVX)
CR10-821J-T (AVX)
CR10-821J-T (AVX)
CR10-510J-T (AVX)
CR10-102J-T (AVX)
CR10-102J-T (AVX)
NE68119 (NEC)
NE68119 (NEC)
Table 3. Bill of Materials
Footprint
0603
0603
0603
0603
0603
0603
0603
SOD-323
SOD-323
0603
0603
0603
0603
0603
0603
0603
0603
0603
0603
0603
0603
0603
SOT-416
SOT-416
Figure 9 shows the PCB layout. The board is made of standard FR4
material 30 mils thick.
The results measured with the circuit in Figure 8, as well as the
simulated results obtained with the model in Figure 9, are shown
in Figures 10 and 11.
Note: The simulated tuning curve in Figure 10 agrees with mea-
sured data, which proves the effectiveness of the above piece-wise
approximation technique.
Note: In the middle of the tuning range there is disagreement
between our model and the measured results. This could be attrib-
uted to the imperfection of the model, which is highly sensitive to
the way different parasitic effects are treated. The other problem of
modeling this oscillator case was the convergence of the harmonic
balance. To facilitate convergence in this case, we kept the number
of harmonics to at least five. The sweeping frequency range is rec-
ommended to keep as close to the oscillation point as possible —
especially when analyzing the middle band area.
In Figure 11, the power response modeled at 7 V was very close to
the measurement. Higher measured power is attributed to the ana-
lyzer calibration (the calibration error of the analyzer is known to be
within a couple of decibels). The general trend of the simulated
results reflects the real VCO response almost exactly, which clearly
demonstrates the model’s effectiveness.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
8
July 21, 2005 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200314 Rev. A