3½ D I G I T, L E D D I S P L AY D I G I TA L PA N E L V O LT M E T E R S
DMS-20PC
4. DISPLAY TEST/HOLD (Pin 9) Function: Pin 9 is a dual-
function pin. On all standard models (without "-H" suffix), tying
pin 9 to pin 1 (+5V SUPPLY) activates the meter's DISPLAY
TEST feature. All display segments, except the decimal points,
will be illuminated. The display will show "1888" ("–1888" if a
negative input signal is present). Do not leave the meter in the
test mode for more than 10 seconds as this will cause the
meter's operating temperature to rise and possibly affect its
performance. Pin 9 must be left open when the test function is
not being used.
On models with the "-H" suffix (DMS-20PC-1-RS-H for example),
pin 9 serves as a DISPLAY HOLD control pin. Tying pin 9 to +5V
SUPPLY (pin 1) on these models will hold or "freeze" the current
display reading indefinitely. Pin 9 must also be left open when
the hold function is not being used. After disabling DISPLAY
HOLD, allow the meter a full 10 seconds to resume normal
calibrated operation before holding a new reading.
The DISPLAY TEST or DISPLAY HOLD pin should normally be
connected, via a selector switch, to pin 1 (+5V SUPPLY). If
automatic, logic-controlled operation is desired, only PNP or
MOSFET transistors should be used. The base or gate of these
transistors should be driven sufficiently hard to bring pin 9 within
0.05V of +5V SUPPLY.
5. DISPLAY ENABLE (Pin 2) Function: On all models, tying pin 2
to pin 1 (+5V SUPPLY) applies full power to the LED display.
This is the normal mode of operating the meter. Leaving
DISPLAY ENABLE open (no connection), only turns off the LED
display. The meter's analog-to-digital converter continues to
sample the input signal. Total current consumption with the
display off is approximately 400µA (0.4mA). This is a very useful
feature if the meter is used in battery-powered equipment.
With the exception of the low-power red led models (DMS-
20PC-X-RL), a regulated voltage lower than +5V SUPPLY can
be used to dim the display intensity. Display intensity control is
best performed with the high brightness, red LED, DMS-20PC-
X-RH model. All low-power red LED models must have DISPLAY
ENABLE tied directly to pin 1 (+5V SUPPLY). Voltages applied
to DISPLAY ENABLE must never be greater than +5V SUPPLY.
6. Gain Adjust: There is a gain-adjust potentiometer on the back
of each meter. It has approximately ±50 counts (±2.5%) range
of adjustment. Since these devices essentially have no zero/
offset errors, a gain adjustment is effectively an overall accuracy
adjustment. Though they may be performed at any point
(except zero), accuracy adjustments are most effective when
performed with higher level input signals. The circuit shown in
Figure 9 provides ±10% range of adjustment.
7. Soldering Methods: All models in the DMS-20PC Series easily
withstand most common wave soldering operations. We
recommend, however, that you evaluate the effects your
particular soldering techniques may have on the meter’s plastic
case and high-precision electrical performance. We recommend
the use of water-soluble solders and thorough cleaning
procedures.
8. Suggested Mating Connectors:
Panel mounted:
Connector housing
Terminal type
Crimping tool
Wire size
Insulation diameter
Stripping length
MOLEX P/N 22-01-2061
MOLEX P/N 08-65-0805
MOLEX P/N 11-01-0037
22 to 26 AWG
0.062" (1.57mm) maximum
0.100 to 0.125" (2.54 to 3.17mm)
Board mounted:
Socket
SAMTEC P/N SSW-106-02-T-S
Applications
DMS-20PC meters are highly versatile devices that can be used in
hundreds of applications. The application circuits chosen for this
section are ones that have historically received many inquiries.
The schematic in Figure 1 shows that the meter's high-impedance
input consists of an op amp powered from a ±5Vdc power supply
(the –5V is internally generated). One can easily see why input
signals applied to (–) INPUT LO and (+) INPUT HI have to be kept
within the power supply rails of ±5V. Also note that only pin 11 has a
current-limiting 909kseries resistor. High input voltages that have
a common ground with pin 3 (5V RETURN) should only be applied
to pin 11 ((+) INPUT HI) and never to pin 12. In these high-voltage
cases, pin 12 should always be tied to pin 3 (5V RETURN).
The schematic also shows that pin 3 is the meter's zero-volt
reference point — regardless of the type of power or signal source
used. This is an important point to keep in mind when a digital or
analog multimeter is used to make system measurements. The
multimeter's negative lead (usually the black one) must be
connected to pin 3 (5V RETURN).
1. Single-Ended Input Configurations: True single-ended
measurements can be made with any DMS-20PC meter. The
circuit of Figure 2 avoids problems normally associated with
ground-loop currents. Separate ground runs should be used
for 5V RETURN (pin 3) and (–) INPUT LO (pin 12).
+
VIN
120 VAC
11
(+) IN HI
12
(–) IN LO
1
+5V SUP
DATEL
UPA-5/500
DMS-20PC-1
8
REF OUT
2
DISPLAY
ENABLE
6
DP1
7
REF IN
3
5V RET
AC to DC Converter
Figure 2. Single-Ended Input Configuration