4.4 Sleep or Silent Mode: Behavior at a Floating LIN-bus or a Short Circuited LIN to GND
In Sleep or in Silent Mode the device has a very low current consumption even during short-circuits or floating conditions on
the bus. A floating bus can arise if the Master pull-up resistor is missing, e.g., if it is switched off when the LIN- Master is in
sleep mode or even if the power supply of the Master node is switched off.
In order to minimize the current consumption IVS in sleep or silent mode during voltage levels at the LIN-pin below the LIN
pre-wake threshold, the receiver is activated only for a specific time tmon. If tmon elapses while the voltage at the bus is lower
than Pre-wake detection low (VLINL) and higher than the LIN dominant level, the receiver is switched off again and the circuit
changes back to sleep respectively Silent Mode. The current consumption is then IVSsleep_short or IVSsilent_short (typ. 10µA more
than IVSsleep respectively IVSsilent). If a dominant state is reached on the bus no wake-up will occur. Even if the voltage rises
above the Pre-wake detection high (VLINH), the IC will stay in sleep respectively silent mode (see Figure 4-6).
This means the LIN-bus must be above the Pre-wake detection threshold VLINH for a few microseconds before a new LIN
wake-up is possible.
Figure 4-6. Floating LIN-bus during Sleep or Silent Mode
LIN BUS
VLINL
VBUSdom
LIN Pre-wake
LIN dominant state
IVS
IVSsleep/silent
tmon
IVSfail
IVSsleep_short /
IVSsilent_short
IVSsleep/silent
Mode of
operation Sleep/Silent Mode
Wake-up Detection Phase
Int. Pull-up
Resistor
RLIN
off (disabled)
Sleep/Silent Mode