Philips Semiconductors
UHF amplifier module
Product specification
BGY204
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).
SYMBOL
PARAMETER
CONDITIONS
VS
DC supply voltage
PL = 0
VC
DC control voltage
PD
input drive power
PL
load power
VS ≤ 6.5 V; ZL = 50 Ω
Tstg
storage temperature
Tmb
operating mounting base temperature
MIN.
−
−
−
−
−40
−30
MAX.
8
4.5
2
4
+100
+100
UNIT
V
V
mW
W
°C
°C
CHARACTERISTICS
ZS = ZL = 50 Ω; PD = 1 mW; VS = 4.8 V; VC ≤ 3.5 V; f = 880 to 915 MHz; Tmb = 25 °C; δ = 1 : 8; tp = 575 µs;
unless otherwise specified.
SYMBOL
IQ
IC
PL
Gp
η
H2
H3
VSWRin
Pn
PARAMETER
leakage current
control current
load power
power gain
efficiency
second harmonic
third harmonic
input VSWR
stability
isolation
control bandwidth
noise power
ruggedness
CONDITIONS
VC = 0.5 V
adjust VC for PL = 3.2 W
adjust VC for PL = 3.2 W
adjust VC for PL = 3.2 W
adjust VC for PL = 3.2 W
adjust VC for PL = 3.2 W
adjust VC for PL = 3.2 W
PD = 0.5 to 2 mW; VS = 4 to 6.5 V;
VC = 0 to 3.5 V; PL ≤ 3.2 W;
VSWR ≤ 6 : 1 through all phases;
VC = 0.5 V
PL = 3.2 W; bandwidth = 30 kHz;
20 MHz above transmitter band
VS = 6.5 V; adjust VC for PL = 3.2 W;
VSWR ≤ 10 : 1 through all phases
MIN.
−
−
3.2
35
40
−
−
−
−
TYP.
−
−
−
−
45
−
−
−
−
MAX.
0.2
0.5
−
−
−
−40
−40
2.5 : 1
−60
−
−
−36
1
−
−
−
−
−85
no degradation
UNIT
mA
mA
W
dB
%
dBc
dBc
dBc
dBm
MHz
dBm
1996 May 21
3