APPLICATION CIRCUIT
BL78XX
Notes:
(1) To specify an output voltage. substitute voltage value for "XX." A common
ground is required between the input and the Output voltage. The input voltage must
remain typically 2.0V above the output voltage even during the low point on the input
ripple voltage.
(2) Ci is required if regulator is located an appreciable distance from power Supply
filter.
(3) Co improves stability and transient response.
Page9