DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

BTS723GW(2007) データシートの表示(PDF) - Infineon Technologies

部品番号
コンポーネント説明
メーカー
BTS723GW
(Rev.:2007)
Infineon
Infineon Technologies Infineon
BTS723GW Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Smart High-Side Power Switch
BTS723GW
Parameter and Conditions, each of the two channels Symbol
at Tj = -40...+150°C, Vbb = 24 V unless otherwise specified
Values
Unit
min typ Max
Protection Functions14)
Current limit, (see timing diagrams, page 13)
Tj =-40°C:
Tj =25°C:
Tj =+150°C:
Repetitive short circuit current limit 15),
Tj = Tjt
each channel
two parallel channels
(see timing diagrams, page 13)
Initial short circuit shutdown time Tj,start =25°C:
(see timing diagrams on page 13)
Output clamp (inductive load switch off)16)
at VON(CL) = Vbb - VOUT, IL = 1 A
Thermal overload trip temperature
Thermal hysteresis
IL(lim)
IL(SCr)
toff(SC)
VON(CL)
Tjt
Tjt
-- 10 12 A
--
9
--
5
8
--
--
8
-- A
--
8
--
--
2
-- ms
59 64 70 V
150
--
-- °C
-- 10
-- K
Reverse Battery
Reverse battery voltage 17)
Drain-source diode voltage (Vout > Vbb) 18)
IL = - 3.0 A, Tj = +150°C
Inverse current 19)
GND current in case of 3A inverse current 20)
-Vbb
-VON
--
--
-- 650
24 V
-- mV
IGND(inv cur)
--
-- 15 mA
14) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
15) not subject to production test, specified by design
16) If channels are connected in parallel, output clamp is usually accomplished by the channel with the lowest
VON(CL)
17) Requires a 150 resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Power dissipation is higher compared to normal operating
conditions due to the voltage drop across the drain-source diode. The temperature protection is not active
during reverse current operation! Input and Status currents have to be limited (see max. ratings page 4 and
circuit page 10).
18) not subject to production test, specified by design
19) not subject to production test, specified by design
20) In case of an inverse current of 3A the both status outputs must not be disturbed.
The neighbour channel can be switched normally; not all paramters lay within the range of the spec
Please note, that in case of an inverse current no protection function is active. The power dissipation is
higher compared to normal operation in forward mode due to the voltage drop across the drain-source diode
Data Sheet
7
V1.1, 2007-09-25

Share Link: 