Data sheet BTS 6133 D
Parameter and Conditions
at Tj= 25, Vbb = 12 V unless otherwise specified
Symbol
Protection Functions 11)
Short circuit current limit (Tab to pin 1,5) 12)
Short circuit current limit at VON = 6V 13)
Tj =-40°C:
Tj =25°C:
Tj =+150°C:
Short circuit current limit at VON = 12V Tj(start) =-40°C:
tm=170µs
Tj(start) =25°C:
Tj(start) =+150°C:
Short circuit current limit at VON = 18V 13) Tj(start) =-40°C:
Tj(start) =25°C:
Tj(start) =+150°C:
Short circuit current limit at VON = 24V Tj(start) =-40°C:
tm=170µs
Tj(start) =25°C:
Tj(start) =+150°C:
Short circuit current limit at VON = 30V 13) Tj(start) =-40°C:
Tj(start) =25°C:
Tj(start) =+150°C:
Short circuit shutdown detection voltage
(pin 3 to pins 1,5)
Short circuit shutdown delay after input current
positive slope, VON > VON(SC), Tj = -40...+150°C
min. value valid only if input "off-signal" time exceeds 30 µs
Short circuit shutdown delay during on condition13)
VON > VON(SC)
Output clamp (inductive load switch off) 14)
at VOUT = Vbb - VON(CL) (e.g. overvoltage)
IL= 40 mA
Thermal overload trip temperature
Thermal hysteresis
IL6(SC)
IL12(SC)
IL18(SC)
IL24(SC)
IL30(SC)
VON(SC)
td(SC1)
td(SC2)
VON(CL)
Tjt
Tjt
Values
Unit
min typ max
-- 110 140 A
-- 105
--
70 90
--
-- 80 110 A
-- 75
--
45 60
--
-- 60 80 A
-- 55
--
33 50
--
-- 40 60 A
-- 40
--
20 35
--
-- 25 40 A
-- 25
--
15 25
--
2.5 3.5 4.5 V
350 650 1200 µs
--
2
39 42
150 175
-- 10
-- µs
-- V
-- °C
-- K
11) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are
not designed for continuous repetitive operation.
12) Short circuit current limit for max. duration of td(SC1) , prior to shutdown, see also figures 3.x on page 13.
13) not subject to production test, specified by design
14) See also figure 2b on page 12.
Infineon Technologies AG