DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

NWK933CG データシートの表示(PDF) - Mitel Networks

部品番号
コンポーネント説明
メーカー
NWK933CG Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
NWK933
SUBGND2 1
TX_ER 2
DGND1 3
TX_EN 4
LNKST 5
ACTST 6
COLST 7
DVDD1 8
RXVDD3 9
RXGND3 10
FDST 11
SPDST 12
PA4 13
RESETN 14
RXVDD2 15
RXGND2 16
48 MINT
47 DVDD3
46 MDC
45 MDIO
44 DGND3
43 RefCLK
42 OSCVDD
41 XTAL1
40 XTAL2
39 OSCGND
38 TXGND4
37 TXVDD4
36 TXREF100
35 TXREF10
34 TXVDD3
33 TXGND3
TP64
Figure 2Pin connections
Functional Description
10Base-T Operation
The NWK933 has three basic modes of operation:
10BASE-T, 100BASE-TX and LOW POWER modes.
The Control block is designed to manage these modes
by starting and stopping the 10M and 100M transceivers
in a well-controlled manner such that no spurious
signals are output on either the MII or twisted-pair
interfaces. Furthermore, it continuously monitors the
behaviour of the transceivers and takes corrective
action if a fault is detected.
Other modes described herein are repeater mode and
reset mode.
25MHz Reference Clock
The NWK933 requires a 25MHz +/-100ppm timing
reference for 802.3 compatible operation. This may
be supplied either from the integrated oscillator or
from an external source. When the integrated oscillator
is used, a suitable crystal must be connected across
the XTAL1 & XTAL2 pins (see “External Components”)
and REFCLK must be tied low. When an external
source is used, it must be input to the REFCLK pin
and XTAL1 must be tied low. XTAL2 must be
unconnected.
10Mb/s Data Transfer on the MII
10Mb/s data is transferred across the MII with clock
speeds of 2.5MHz. The MAC outputs data to the
NWK933 via the MII interface, on the TXD[3:0] bus.
This data is synchronised to the rising edge of TX_CLK.
To indicate that there is valid data for transmission on
the MII, the MAC sets the TX_EN signal active. This
forces the NWK933 device to take in the data on the
TXD[3:0] bus. This is serialised and directly encoded
as Manchester data, before being output on the TXOP/
TXON differential output for transmission through 1:Ö2
magnetics and onto the twisted-pair.
The transmit current is governed by the current through
the TXREF10 pin, which must be grounded through a
resistor as described in “External Components”.
RX10 Clock Recovery
The NWK933 employs a digital delay line controlled
by the 100MHz Synthesizer DLL to derive a sampling
clock from the incoming signal. The recovered clock
runs at twice the data rate (nominally 20MHz). When
a signal is received from the Signal Detect block, it is
used to strobe Link Pulses and Manchester encoded
serial data.
2

Share Link: 